Furnace troubleshooting guides
479 guides. No heat, short cycling, ignition and blower problems on gas and electric furnaces. Each one lists the likely causes and what to check, in order.
All brands (42)
- Blower cycles on and off
On an electric furnace, a blower that keeps starting and stopping is usually the thermostat or the high limit, not the motor. If the elements cycle al - Blower runs, not enough heat
The blower is moving air but it feels cool at the registers. On an electric furnace that means some or all of the heating elements are not energizing. - Blowing cold air
The blower is running, but the air at the registers feels cold. Before opening anything up, confirm whether the burners are actually firing, because a - Board shows "flame sensed with no call for heat"
When the board throws a flame sensed with no call for heat code, I think gas valve first. The control is seeing flame when the thermostat isn't asking - Can't pull oil (distance/lift)
Every fuel pump has a limit on how far and how high it can pull oil. When the tank sits too far away or too far below the burner, the pump starves and - CO in flue / poor combustion numbers
Carbon monoxide in the flue or poor combustion numbers on the analyzer. Read the pattern. Low CO2 with high O2 and CO means excess air is too high or - Cold air blast at start / blower never stops
A cold blast at the start of a cycle, or a blower that never stops, is a fan control problem. Look at what the fan switch or the delay settings are se - Combustion gas / odour in house, flu-like symptoms
If the house smells like exhaust or people are getting headaches, nausea and flu-like symptoms with the heat on, treat it as carbon monoxide until pro - Cycles on limit (not lockout)
The furnace shuts off on the high limit and restarts when it cools down, with no lockout. The burner is heating the exchanger faster than the air can - Does not start
Furnace won't start. Go through the control circuit in order. - Flame burns a few seconds then out
If your oil burner lights, burns a few seconds and then drops out, the control is telling you it lost the flame or never really proved it. That can be - Flame conditions table
Read the flame and it tells you how the furnace is burning. A good flame is soft blue, with no yellow tipping, lifting, flashback, pop, float or rollo - Heat exchanger leak
Heat exchanger leak is a CO risk. Confirm it, don't guess. Test and report. - High blower-door ACH50 (>3)
Blower-door test result over 3 ACH50 means the house envelope is leaky. That drives drafts, high heating and cooling bills and humidity problems, and - High fuel consumption
If your oil bill keeps climbing and the weather has not changed, the burner is probably wasting fuel. Usually the nozzle is worn, the chamber is dirty - High stack temperature
When I see a high stack temperature on an oil furnace, the first thing I look at is the heat exchanger. A coat of soot acts like insulation, and the h - High stack temperature / low efficiency
A high stack temperature means heat is going up the flue that should be going into the house. Confirm the reading with a calibrated thermometer, and k - Indoor blower runs, outdoor unit dead
Indoor blower runs but the outdoor unit is dead. The blower running proves you have line voltage and low voltage at the furnace, so I go after what li - Limit opens
If your furnace shuts the burner off partway through a cycle, the high limit is usually doing its job. It opens when the heat exchanger gets hotter th - Locks out — oil but no ignition
The burner runs and oil is being delivered, but the flame never lights, so the primary control shuts the unit down on safety. Shut off the service swi - Low CO2 (<8 %)
A CO2 reading under 8 percent on a combustion test means too much air or too little fuel in the mix. Other readings: high CO2 with smoke points the ot - Low draft / blowback
Low draft or blowback means the flue gases are not leaving the building the way they should, and that can put carbon monoxide into the living space. C - Modulating furnace won't modulate
Modulating furnace stuck at one firing rate. The furnace may be fine. It just isn't being told to modulate. - Negative house pressure, backdrafting, infiltration
Your house can end up under negative pressure when fans and combustion appliances pull more air out than comes in. That's when a furnace or water heat - No heat
Thermostat is calling for heat but the furnace does not start or does not light. - No heat (ignition stage)
Generic sequence - Noisy
Noisy oil burner. Find where the noise lives first: motor end, pump, stack or the tank. Most of the time it is something loose or worn that takes minu - Noisy registers, drafts, blower overamps/ECM noise, coil freezing
Noisy registers, drafts, a blower drawing high amps or ECM noise, and a freezing coil all point to airflow that has nowhere to go on a zoned system. W - Not running / fault code
If a furnace blower motor will not run or the control shows a fault code, don't jump straight to the motor. These setups have a control module that de - Oil + ignition OK but no flame
Oil is flowing, spark is good, still no flame. Usually a spray problem or an air problem. Check the nozzle and pressure first, then draft and air sett - Oil on floor
Oil on the floor around the furnace is not something to wait on. It is a fire and cleanup problem, and it usually means a fitting has loosened or the - Pressure switch open / stuck
Pressure switch open or stuck. Usually the board will tell you which, by the flash code. - Puff-back / delayed ignition
A puff-back or delayed ignition is a small oil explosion in the chamber because the oil sprayed for a moment before the flame lit. It can blow soot ou - Reduced airflow, hot motor
Weak airflow and a motor that runs hot on a belt-drive furnace blower. A hot motor is working too hard, so confirm the cause before it burns out. Turn - Reduced pressure, smoky shutdowns, lockouts
Pressure drops, smoky shutdowns, random lockouts. Classic air in the fuel. Bleed it first. If it keeps coming back, find the leak or add a deaerator. - Rollout switch tripped
Rollout tripped. Flame rolled out of the combustion chamber. Treat it as serious. - Short cycling
Nine times out of ten when a gas furnace lights, runs a couple of minutes, shuts off and starts over, it is a plugged filter or a dirty flame sensor. - Smoke, soot, odour, pulsation
Smoke, soot, a fuel smell in the house and a burner that pulses are all the same story: the oil is not burning cleanly. What I usually find is a bad s - Starts but locks out — no oil at nozzle
Most times I get called for this one, the oil never makes it to the nozzle, so the burner itself is fine. The motor starts, the control waits out its - Too little / too much air
If rooms get too little air or too much, the first thing to look at is the total external static pressure the blower is working against. The blower ta - Unsatisfactory heat (short cycles / uneven / not enough)
Unsatisfactory heat on a furnace usually shows up as short cycling, uneven rooms or just not enough warmth. In my experience it is rarely one thing. A - Water flows with furnace off
Water keeps flowing to the humidifier after the furnace has shut down. Left alone it can overflow the pan, run down the drain constantly, or stain the
Allied (40)
- Annual planned service inspection
Items a service technician should check during the yearly inspection. Shut off power to the unit first. - Annual service checklist
What I usually find on a furnace that has not been looked at in a few years is a dirty blower wheel, a plugged filter and a slightly loose connection - Blower access panel and carbon monoxide hazard
Carbon monoxide risk. On the Allied A95, A93, 95G1 and 92G1UH, if the blower access panel is off or loose while the blower or burners run, gas fumes t - Burner assembly cleaning
Clean the burners and inspect the crossovers for blockage. - Change blower speed tap
Change the blower speed tap on the integrated control to match the heating or cooling speed needed. - Check temperature rise and adjust blower speed
Temp rise check on the Allied. Run it until supply and return temps settle, then measure. Out of range means a speed change. - Check venting and combustion air on non-direct vent installs
Test for spillage and proper draft after startup when the furnace shares a vent with other gas appliances. Carbon monoxide poisoning risk: do this for - Checking a shared vent after this furnace is removed or replaced
If this furnace was on a common vent with other gas appliances, the vent may now be too large for the remaining appliances. Test each remaining applia - Checking gas flow rate (approximate)
Clocking the meter. Quick way to check actual gas input. Run furnace 5 min first so it is steady. Only this appliance on the meter. Compare against th - Clean the burner assembly
Clean the burners and crossovers after removing the burner and manifold assembly. - Clean the heat exchanger
Remove the heat exchanger assembly for cleaning. Protect the floor in front of the furnace. - Direct vent termination layout (roof and sidewall)
Intake and exhaust must share the same pressure zone, and the two pipes should be as close together as possible at the termination. - Electrical checks on the furnace
A basic electrical checkout on the Allied furnace is quick and catches a lot. You are looking for loose connections, low supply voltage and a blower m - Exhaust and air intake pipe check during startup
Use this when the furnace shuts off at the pressure switch, or when a flame rollout switch opens. Both often trace back to the venting. Before opening - Exhaust pipe transitions and sizing
Pipe size comes from table 5, and exhaust and intake must be the same diameter. Step-ups should be kept as short as possible. Getting this wrong shows - Exhaust piping installation
Exhaust runs under positive pressure and must be sealed completely to keep flue products out of the living space. - Exhaust transitions in upflow and horizontal runs
Figures 22 and 23 in the Allied manual show typical exhaust connections for upflow and horizontal runs. The short version: you can go up in pipe size, - General vent termination requirements
The furnace is Category IV in both non-direct and direct vent. Termination location is limited by local codes. Without local codes, use NFPA 54 (US) o - Heat exchanger removal, cleaning and reinstallation
Clean the heat exchanger when it is fouled. Remove it from the cabinet, wash it, rinse it fully and put it back in the same position. Steps 1 to 20 ar - Horizontal clearance figure (values not readable)
This one is about Figure 15, the horizontal clearance drawing for the Allied furnace. It covers top, front, back, ends, vent and floor. Read the numbe - Install condensate trap and drain
This covers setting up the condensate trap and drain line on the furnace. A high efficiency furnace makes condensate every cycle, and a trap or drain - Install sidewall vent termination
Field-supplied sidewall termination. Heights and spacing matter. Get them wrong and you get blocked pipes, recirculated flue gas, or frozen terminatio - Installation code requirements
Local code comes first. Without it, the National Fuel Gas Code (ANSI Z223.1/NFPA 54) applies in the USA and CSA-B149 in Canada. These units are CSA ce - Intake piping for direct vent installations
On a direct vent Allied furnace, the combustion air comes from outside and the flue goes outside, so the intake pipe has to be run to the exterior. Wh - Intake piping for non-direct vent installations (air from indoors)
On a non-direct vent install, the furnace takes its combustion air from the room, so the air intake pipe is really just a protected opening. Before re - Joint cementing procedure for plastic vent pipe
Cement joints per ASTM D2855. Time matters, so work fast once primer goes on. - Keep the furnace away from contaminated combustion air
Exposure to certain chemicals in the combustion air causes safety and performance problems, heat exchanger rusting and early failure. - Measuring manifold gas pressure
Manifold pressure is measured at the gas valve outlet with a manometer after the furnace reaches steady state. It tells you whether the valve is deliv - Measuring supply gas pressure
Supply gas pressure is what the utility or the piping hands to the furnace gas valve, and you measure it with the furnace firing at maximum rate. If i - Platform installation of a horizontal unit
Used for horizontal units set on a raised platform or suspended in an attic or crawl space. - Protecting walls from acidic flue gas
Flue gas from a condensing furnace can be slightly acidic and can stain or eat into some building materials at the termination. A protective shield is - Remove bottom panel for horizontal or bottom return installs
These Allied A95UH, A93UH, 95G1UH and 92G1UH furnaces come with a bottom panel already fitted. I have seen guys set the furnace on a bottom return ple - Replacing a furnace that shared a common vent
When the new Allied furnace is vented on its own and the old furnace used to share a common vent, the remaining appliance is left on a vent that is no - Return air connection and sealing
Improper return connections can allow combustion products into the living space. - Sizing intake and exhaust vent pipe
Use the tables and flowchart to size pipe. Both intake and exhaust must use the same pipe diameter. - Suspended or platform install of horizontal furnace
Horizontal units can hang from roof rafters or joists, or sit on a raised platform. Plan for service and drain access in either case. - Unit fails to operate
Check these items in order before calling for service. - Upflow 5-ton units with 1800 cfm or more airflow
Upflow 20C and 20D (5 ton) units that need 1800 cfm or more have to be set up with one of the listed return air arrangements. Too little return openin - Venting configuration (direct vent or non-direct vent)
The furnace can go in as a Direct Vent or a Non-Direct Vent unit, and the choice changes where the combustion air comes from. With Direct Vent the air - Winterize and clean the condensate trap
Condensate trap care on the Allied, for winterizing or routine cleaning. Before opening anything, turn the furnace power off. A trap can hold dirty wa
Carrier (2)
- Burners will not light or stay lit - Carrier 58SB0A/58SB1A
Ignition-proving problems (codes 34 and 14) worked through with the component test. - Furnace not responding to thermostat - Carrier 58SB0A/58SB1A
No heat or cool response although the control has power. Flowchart-based checks for the single-stage 58SB control.
Daikin (7)
- Commissioning wizard overview
The guided set-up walks the installer through the full commissioning process so the system is configured correctly before handover. Random access to a - Control display blank, furnace dead - Daikin DR96TN/DD96TN
The furnace does nothing and the 7-segment display on the integrated control module shows nothing (the troubleshooting chart lists this as LED status - Furnace not paired with R-32 cooling - disable A2L function - Daikin DR96TN/DD96TN
The DR96TN/DD96TN control ships with the R-32 (A2L) leak-mitigation function ON. If the furnace is used with a non-R-32 cooling system or no sensor is - No heat - Daikin DR96TN/DD96TN
Thermostat calls for heat but the furnace does not start, light or deliver heat. Step-by-step check of the heating sequence from the manufacturer flow - Thermostat location and mounting
Pick a spot that gives a true room reading and mount the thermostat level, about 5 ft off the floor, on an interior wall. - Thermostat messages and their priority
The thermostat shows four message types: status, alerts, reminders and prompts, and learn more/tips. Alerts take priority over all other messages. - Thermostat shows communication error or equipment not recognized
The thermostat reports a communication error or does not recognize the equipment after installation.
Goodman (109)
- Airflow lower than demanded, furnace runs on low stage when high stage is expected
Not enough air moving. Control runs the furnace on low stage when it should be on high. Same story as most airflow calls, check the air path. - Alternate combustion air opening (upflow or horizontal)
When the alternate vent location is used (horizontal left side down, or downvent vertical), an alternate combustion air opening can be used. The locat - Alternate vent/flue location (upflow or horizontal left)
The alternate vent exit is the large hole in line with the induced draft blower outlet. It is not available on counterflow models. - Annual inspection checklist
The furnace should be inspected by a qualified installer or service agency at least once a year, at the start of the heating season. Check the flue, c - Auxiliary limit control (location and purpose)
On these select 90% and 95% furnaces there are two auxiliary limits on the blower housing, one on each side. They are there for the horizontal and cou - Auxiliary limit switch open (blower compartment)
This one means the auxiliary limit in the blower compartment is open, and the furnace will not run until it closes. It is a safety, so it is telling y - Blower motor does not have enough information, fails to start 40 consecutive times
The blower motor failed to start 40 times in a row, and the control says it lacks the information to run it properly. That can mean a data problem in - Blower motor fails to start after 10 consecutive tries
Circulator blower motor tried to start ten times in a row and failed, so the furnace is down. - Blower motor horsepower mismatch
The control checks the motor horsepower stored in its shared data set against the circulator blower motor that is actually installed. When they do not - Blower motor loss of rotor control or high current trip
This fault means the circulator blower motor lost track of its rotor, or it saw a surge of current, and the control shut the furnace down. In plain wo - Blower motor operating in power, temperature or speed limit (reduced airflow)
Furnace is limping along at reduced output. The blower motor has backed itself off on power, temperature or speed because airflow isn't what it expect - Blower motor over or under voltage, or over temperature on power module
I see this one on jobs where the power to the house is flaky or the furnace sits in a hot spot. The motor shuts itself down when line voltage is too h - Burner flame appearance check
Check the flames with the burner compartment door installed. Flames should be stable, quiet, soft and blue. Dust can cause orange tips, but the flames - Canadian vent system requirements
Canadian installs must follow CAN/CSA B149.1-15. All vent parts, primer and cement must be ULC S636 listed and match one manufacturer's system. - Check and adjust temperature rise
Temperature rise depends on airflow and firing rate. An incorrect rise can cause condensing or overheating of the heat exchanger. - Check auxiliary limit control (blower housing)
There are two auxiliary limits on the blower housing, one on each side, and they can be manual or automatic reset. Their job is to stop the burners if - Check blower (inducer) pressure switch
The pressure control stops combustion if venting is restricted or blocked. A/GMVC96 and A/GCVC models also have a front cover pressure switch in serie - Check burner orifices
These furnaces leave the factory with #45 natural gas orifices. You only change them for altitude derate or an LP conversion. What I run into most is - Check duct static pressure
Adds the return and supply static readings to get total external static pressure, then compares it with the blower tables. - Check ECM control/end bell
Checks the thermistor, capacitors and connector resistance in the control/end bell. - Check ECM high voltage power circuits
This is the test for line voltage getting to the ECM blower motor through the 5-circuit power connector. Straightforward once you know the pin pairs. - Check ECM low voltage control circuit
Low voltage side of the ECM. Checks the DC control signal between the control board and the motor. - Check ECM motor windings
This check looks at the three phase windings in the ECM motor for imbalance, an open winding or a short to the motor shell. It is done with an ohmmete - Check flame rollout switch
Manual reset rollout switch on the burner bracket. It opens on flame rollout, flame impingement on the heat shield or over-firing. The blower runs con - Check gas input by clocking the gas meter
Time one revolution of the meter's smallest dial with the furnace at steady firing, then work out the input in BTU/hr and compare it with the nameplat - Check induced draft blower motor
The induced draft blower is the motor that pulls flue gases through the heat exchanger and starts the whole ignition sequence. If it does not run, not - Check line voltage to the furnace
Confirm the supply voltage at the junction box and at the blower while it runs. - Check primary limit control
The primary limit is a non-adjustable, automatic reset bi-metal control on the heat exchanger. It should read open only when the heat exchanger is hot - Check primary limit control (90% furnaces)
The primary limit on these 90% furnaces is the enclosed disk with the colored tab, mounted to see heat exchanger temperature. Most times I get called - Check the hot surface igniter
When one of these Goodman/Amana single-stage units throws 8 or 11 flashes, locks out or just won't light, the hot surface igniter is usually the first - Check thermostat and low voltage wiring
Decides whether a no-heat or no-cool problem is in the thermostat or the wiring, or in the furnace. - Check transformer and control circuit
If the furnace is completely dead, no lights, no blower, the first question is whether the 24 VAC control power is there. This check answers it fast a - Check transformer phasing on unmarked transformers
Some electronic boards that use flame rectification need the low voltage side to be in phase with the line side. If a transformer has no phasing marks - Check wiring
A visual and continuity check of the wiring on the GMVC96 family furnace. Do it with the power off and confirmed dead, since the wiring carries line v - Checking unit grounding
Before you trust any electronic control on this Goodman furnace, confirm it has a solid ground. The gas piping must never be used as the electrical gr - Circulator blower motor not running when it should be
Circulator blower not running on a call for heat or airflow. - Clocking a gas meter
Clocking the meter tells you how much gas the furnace really burns, which feeds the BTU input calculation in the heating performance test. Run the fur - ComfortNet data line check - Goodman *MVC95/*CVC9
How to check the two communication wires (data 1 and data 2) when the furnace, thermostat and outdoor unit are not talking. - Concentric and side wall vent kits
Concentric and side wall kits are the two ready-made options for direct vent terminations. What I usually see go wrong is someone using the side wall - Condensate drain system general rules
Rules for the condensate drain trap and field drain line. - Condensate drainage system check
On these condensing Goodman furnaces the drain tubes, trap and field drain line need to be checked every year and cleaned as often as needed so conden - Condensate switch open
The furnace won't run because the condensate switch is open. The switch trips when water backs up in the drain pan or trap, and the board shuts the fu - Connecting the CoolCloud app when the 3-digit code is not visible
The CoolCloud app normally pairs using the three-digit access code you read through the sight glass on the control. If you cannot see all three digits - Control display blank, furnace dead - Goodman/Amana 9-speed ECM furnaces
The furnace does nothing and the 7-segment display on the integrated control module shows nothing (the troubleshooting chart lists this as LED status - Counterflow horizontal, left side down - drain setup
Drain trap and hose setup for a counterflow furnace laid on its left side. Needs at least 5.5 in clearance under the trap. - Counterflow horizontal, right side down - drain setup
Drain trap and hose setup for a counterflow furnace laid on its right side. Needs at least 5.5 in clearance under the trap. - Counterflow vertical - drain exit side
Counterflow furnace installed vertically. Left side is preferred. Drain out the right side requires moving the trap outside the cabinet. - Customer bundle: auxiliary condensate switch wiring
Aux alarm input on the GMVC96 family control. It's meant for a condensate switch, and compatible CO2 sensors or fire alarms can use it too. Switch is - Data not yet on network
No data, no run. Control comes up with an empty shared data set, so it will not fire. Almost always a new board or a fresh install. Model data lives o - Delayed ignition - rough light-off
Delayed ignition. Gas builds up in the chamber, lights late, thump. Gas work, licensed gas tech only. No bypassing safeties. - Delayed ignition check
Delayed ignition is when the gas-air mixture sits in the chamber a moment too long before it lights. When it finally catches, it can go off with a ban - Direct vent (dual pipe) routing and terminations
Direct vent uses separate combustion air intake and vent pipes, run horizontally through a side wall or vertically through the roof. - Direct vent (dual pipe) termination
On a direct vent install, what I always check first is that the intake and the vent end up in the same pressure zone. If they do not, the pressure swi - Direct vent combustion air intake connection
Connect the intake pipe using the supplied rubber coupling, a plastic coupling or the RF000142 coupling. Support the vent so the rubber elbow carries - Display blank, furnace dead - Goodman *MVC95/*CVC9
The two-digit display shows nothing and the furnace does nothing. A ComfortNet thermostat may show INTERNAL FAULT EE with Call for Service. - Elbow dimensions for vent piping
For the Goodman vent and intake piping, use medium-radius (1/4 bend DWV) or long-sweep elbows that meet ASTM D3311. A tight elbow adds more resistance - Electrical connections and wiring harness rules
Before you touch any wiring on this furnace, read these rules. Line voltage and low voltage control wiring share the same cabinet, and mistakes can ca - Electrostatic discharge (ESD) precautions
The integrated control module is a circuit board with static-sensitive parts, and a charge you cannot feel can still damage it. Damage often does not - External gas valve error (valve not energized when it should be)
The control is calling for the gas valve and it isn't energizing. Before touching anything, turn the power off. This points at the valve circuit or th - Flame detected when no flame should be present
Control sees flame with no call for heat, so the inducer and circulator blower keep running. - Flame sensor cleaning and signal check
Dirty flame sensor. Fuel or air supply leaves a nearly invisible film on the rod. It insulates the rod and drops the flame signal. Qualified servicer - Flame sensor microamp check
Flame current is measured in series with the sensor. The integrated ignition control needs 1 to 4 microamps to prove flame. Contaminated fuel or air c - Flashback - burning inside the burner venturi
Flashback is when the flame burns back inside the burner venturi instead of at the ports. You may see it at light-up, as the burner warms, or hear a p - Flashback at ignition or burner shutoff
Flashback is when the flame burns back into the burner venturi because the burning speed is faster than the gas and air coming out of the port. You se - Fossil fuel application with a heat pump
This furnace can pair with a heat pump as a fossil fuel system, where an outdoor temperature sensor decides whether the heat pump or the gas furnace d - Front cover pressure switch tube relocation (horizontal, left side down)
On a Goodman GMVC96 laid horizontally with the left side down, the front cover pressure switch tube has to be moved to the lower port on the collector - Furnace fails to operate, control LED shows no signal
Dead board. No LED, no display, furnace does nothing. Start at power, work toward the control. Most of the time it is a tripped breaker, a door switch - Furnace in lockout - how to reset it
The furnace has stopped after its ignition retries and the control is flashing 1 on the LED. That is a lockout, and resetting it only clears the sympt - Gas valve (two-stage) and front cover pressure switch
The two-stage valve needs 24V between common and the low fire (main) coil before it will open. The front cover pressure switch sits in series with tha - General ECM blower checks
Before you condemn an ECM blower motor, go through the basic mechanical and electrical checks. Many motors are replaced when the real problem was a lo - Grounding fault
The furnace doesn't run and the board is showing a grounding error. The control needs a solid ground and a good neutral before it will light anything, - Heating performance test
Before you chase a fault code on a furnace that runs but does not heat well, find out whether it is actually putting out what the rating plate says. A - High stage pressure switch open, furnace on low stage only
Induced draft blower runs but the furnace only operates on low stage. - High stage pressure switch stuck closed at start of heating
The furnace runs fine on low stage but won't go to high. The high stage pressure switch is reading closed at the start of the cycle when it should be - Horizontal installation: suspension, leveling and drain
Horizontal furnaces need proper support, a level end-to-end set-up with a slight forward tilt, and a trap drop for condensate. Crawl space units must - Igniter fault or improper grounding
Furnace is locked out on an igniter circuit error. Control sees a bad igniter circuit or a bad ground. Check wiring and ground first, then igniter, th - Integrated ignition control board checks
The control is not field repairable and must be replaced as a whole. Ground and polarity must be correct. The trial for ignition is 4 seconds. The con - Internal gas valve error (valve energized when it should not be)
Gas valve energized with no call. Bad one. Valve shouldn't have power unless the control asks. Kill power first. - Invalid memory card data
This one shows up when the control module looked at the shared data set on the memory card and refused it. Usually the card doesn't match the furnace - Lockout after excessive ignition retries (3 total)
So the furnace tried to light three times and gave up, and now it's locked out. That just means the control never proved flame, so it shut the gas off - Loss of communication with circulator blower motor
The integrated control module and the circulator motor have stopped talking to each other, and the furnace won't run. What I usually find is a plug th - Loss of flame after establishment
Burners light, then drop out. Flame is established and then it is gone. Often a few seconds later it tries again. Look at what changes right after lig - Low flame signal, furnace runs normally
The furnace is still lighting and heating, but the flame sense micro amp signal is lower than it should be. A low signal can drop out and cause nuisan - Low stage pressure switch contacts not closed
The control is looking for the low stage pressure switch to close and it isn't seeing it. That switch tells the control the inducer is pulling a draft - Low stage pressure switch open, induced draft blower runs continuously
Induced draft blower keeps running and the furnace does not continue to operate. - Low stage pressure switch stuck closed at start of heating
The board sees the low stage pressure switch closed before the inducer has even started, so it won't go any further and the furnace won't run. The swi - Measure and adjust manifold gas pressure (36J54 valve)
Manifold pressure is measured with burners operating. Only small variations should be made with the valve pressure regulator. Do not derate the furnac - Measure inlet gas supply pressure
Measure supply pressure with burners firing and other gas appliances on the same line running. Supply must fall within the rating plate range. - Multiple direct vent furnaces at one termination
Multiple direct vent Goodman furnaces on one roof or one side wall. Same clearances as a single unit, per pair. Keep terminals level. - No heat - Goodman/Amana 9-speed ECM furnaces
Thermostat calls for heat but the furnace does not start, light or deliver heat. Step-by-step check of the heating sequence from the manufacturer flow - No ignition - voltage checks at the ignition control
Step-by-step live checks to find where the sequence stops. Take care, line voltage is present. - Non-direct vent (single pipe) termination
Non-direct vent, single pipe, means the furnace pulls its combustion air from the room and only the flue pipe goes outside. It can exit horizontally t - Open fuse, no furnace operation
The furnace is dead or won't run, and the 3-amp control fuse on the board has blown. That fuse protects the 24 V side, so a blown one almost always me - Poor combustion / flame problems - Goodman/Amana GM9C96
Burner flame is unstable, lifting, yellow or the furnace has repeated flame or pressure switch problems with no single clear code. The manual lists th - Primary (high) limit open, circulator blower runs continuously
The primary limit circuit is open, so the furnace will not fire, and the circulator blower keeps running to cool the heat exchanger. Before you touch - Reversed line polarity
A polarity error means hot and neutral are swapped at the furnace, or the ground isn't good. The board checks it before it'll run, so it stays locked - Rollout switch open
The rollout switch has opened and the furnace will not run. A rollout switch trips when flame or hot gas spills out of the burner compartment, so trea - Temperature rise out of range - Goodman *MVC95/*CVC9
Supply air too hot or too cold compared to the rating plate rise range. - Test the ECM motor with the UltraCheck-EZ diagnostic tool
The UltraCheck-EZ (part UTT-01) is the preferred tool to diagnose the ECM motor. Use the LED and button status to decide the next step. - Upflow horizontal, left side down - alternate drain setup
Alternate drain route using the RF000142 coupling for an upflow furnace on its left side. - Upflow horizontal, left side down - drain setup
Drain trap and hose relocation for an upflow furnace laid on its left side. Needs at least 5.5 in clearance under the trap. Hose cut lengths depend on - Upflow horizontal, right side down - drain setup
Drain trap and hose relocation for an upflow furnace laid on its right side. Needs at least 5.5 in clearance under the trap. - Upflow vertical - drain exiting left side
Routing the condensate drain out the left side of an upflow furnace uses a hose and fitting kit. The hose cut point depends on the cabinet width, so m - Upflow vertical - drain exiting right side
This is the hose and fitting job for sending the condensate drain out the right side of an upflow furnace. It looks fussy but it is just four connecti - Upflow vertical install - drain exit side
Upflow GMVC96 family furnace standing vertical. Leave the condensate trap and hoses the way the factory ran them. Drain can come out left or right. Do - Vent piping cement and solvent safety
PVC and ABS solvent cement burns and the vapors hurt. Treat it with respect. Follow the pipe maker's directions for cut, clean and cement. - Vent termination heights and sealing
Heights and sealing for vent and combustion air terminations. Applies to roof and wall. Snow burial and poor seals are the usual faults. - Vent/flue pipe sizing and elbow rules (non-direct vent)
Rules for building the vent/flue run on a non-direct vent install. The length table itself did not come through legibly on these pages, so take the ma - Venting check when an existing furnace is removed from a shared vent
If the old furnace was on a vent that also serves other gas appliances, the vent may now be too large for the remaining appliances. Test each remainin
ICP (4)
- Check inlet gas pressure
Low inlet gas pressure on the ICP F9MAE and G9MAE keeps you from setting the right input and causes ignition and pressure switch faults. Check it with - Component self-test
Component self-test on the ICP F9MAE and G9MAE modulating variable-speed furnaces. Runs the inducer, checks gas valve communication, heats the igniter - No heat - control does not respond to thermostat
So your ICP F9MAE or G9MAE shows the LED heartbeat, there are no stored fault codes, but the furnace just ignores the thermostat. That's actually a he - Reading and retrieving status codes
Status LED: heartbeat (bright-dim) = normal; code = short flashes (first digit) then long flashes (second digit). Up to 7 codes are stored and survive
Johnson Controls (1)
- No heat - SmartValve SV9501/SV9502 pilot does not light or main burner does not come on
Step-by-step check of the intermittent-pilot SmartValve ignition on RGAC/SGAC units.
KeepRite (4)
- No heat, control ignores the thermostat - KeepRite (F/G)9MXE
KeepRite (F/G)9MXE. Green status light pulses heartbeat, so the board is alive. Furnace ignores W, Y or G. Control is fine on its own, so the call is - No heat, control ignores the thermostat - KeepRite (F/G)9MXT
The status light on the KeepRite (F/G)9MXT is pulsing a heartbeat, but the furnace won't respond to W, Y or G. A heartbeat tells you the control has p - Reading stored codes and component test - KeepRite (F/G)9MXE
How to recall the last fault and run the built-in component test. - Reading stored codes and component test - KeepRite (F/G)9MXT
How to recall the last fault and run the built-in component test.
Lennox (18)
- AM radio static during ignition
If you hear AM radio static while the ignitor is energized on a Lennox G43UF, that is the ignitor doing its thing. The hot surface ignitor on these Su - Blower motor does not run - Lennox SL280UHV ECM checks
The variable-speed blower on a Lennox SL280UHV or SL280UHNV is an ECM, which means it is a motor with its own control module, and it will not run unle - Burners light, then the furnace shuts down early
The burners light but the furnace shuts off before the thermostat is satisfied. - Display shows two horizontal bars (soft disable) - Lennox SL297NV
Two horizontal bars on the 7-segment display. Lennox SL297UHNV in an iComfort system. The thermostat found a device on the RSBus it doesn't recognize. - EL296UHV: normal gas heat sequence (what should happen after a call for heat)
Use this to see where a stuck furnace is stopping. Times are from the manual for this series. - EL296UHV: what the display and the diagnostic button are telling you
The EL296UHV control has a seven-segment display and a single push button, and that button is your whole service tool. Hold it for different lengths o - Furnace will not run (no heat) - Lennox EL195UHNE
Quick checks from the manual when the EL195UHNE does not start on a call for heat. - Furnace will not run (no heat) - Lennox SL297NV
Before opening any panel on the Lennox SL297UHNV, check that the thermostat is actually calling and the furnace has power, gas and a clear filter. The - Furnace will not run - Lennox SL280UHV checklist
SL280UHV / SL280UHNV furnace does not start on a heat call; basic checks from the installation manual before deeper diagnosis. - Heat call: inducer does not start but cooling and fan work
This is the one where the thermostat is calling for heat and the furnace just sits there, but the cooling and the fan work fine. That tells you the 24 - Ignitor glows but burners do not light
Inducer runs, the ignitor heats up and glows, and then no flame. What I usually find is gas pressure that is out of range, a loose plug on the gas val - Indoor blower does not run - Lennox EL195UHNE
Constant-torque ECM blower motor check on the EL195UHNE. The motor needs 120 VAC on J48 and 24 VAC (12-33 VAC) on one speed tap of J49. - Indoor blower does not run - Lennox ML180UHE
Constant-torque ECM blower motor check on the ML180UHEK. The motor needs 120 VAC power on J48 and 24 VAC (12-33 VAC) on one speed tap of J49. - Indoor blower will not run
Blower dead. No heat air, no cooling air, no continuous fan. Same symptom on every call means the problem is the motor, its power, or the board's outp - Inducer runs but the ignitor does not warm up
The inducer comes on with a heat call but the ignitor never glows and no flame follows. The control flashes the pressure switch code about 2.5 minutes - Poor ignition or combustion resonance - Lennox EL195UHNE
Burner is slow/hard to light or runs with a loud resonance (rumble/howl). On the EL195UHNE this is usually the air orifice in the air intake coupling, - Poor ignition or loud combustion resonance - Lennox SL280UHNV
SL280UHNV (ultra-low NOx air/gas burner) has trouble lighting or lights with a loud resonance. Hard ignition means too much combustion air (air orific - Two horizontal lines on display (soft disable) - Lennox communicating
The control shows two horizontal lines on its 7-segment display (damper module or EIM: green LED 3 s on / 1 s off). The thermostat found a device it d
Midea (2)
- No light and no fan - furnace does not start
Furnace shows no LED activity and the blower does not run on a call for heat or fan. - Resetting a locked-out furnace
If a Midea BGH96M furnace tries to light a few times and fails, the control locks out to protect itself. This covers the 96% AFUE two-stage models (06
Navien (115)
- Adjust gas valve offset using a digital manometer
Alternative to the analyzer method. Measure the offset pressure at the offset port at low fire. - Adjust gas/air ratio using a combustion analyzer
Set the CO2 with a combustion analyzer, which the manual recommends. Confirm high altitude and gas type first. - Alternate drain piping using PVC or CPVC
The factory rubber hoses at the trap can be used with rigid PVC or CPVC drain piping. Match the hose to the pipe size and seal with a coupling or bush - Annual service: burners, fan and electrical checks
Component inspection items for annual service. The hot surface igniter is fragile. - Annual service: furnace operation checks
Checks a technician should run during annual inspection to confirm normal operation. - Approved vent and termination components
Approved components are listed by manufacturer. Only the part numbers shown in the manual are approved for this appliance. - Auxiliary drain pan under furnace over finished space
If the unit is installed over a finished ceiling or living area, install an auxiliary condensate drain pan under the entire unit. The pan must extend - Check furnace input rate
Calculate input from the gas heating value and the time for the meter dial to move 1 cu ft. Adjustments to burner manifold pressure must be made with - Check horizontal vent slope and support
Confirm horizontal vent runs drain condensate back toward the furnace and are supported correctly. - Check inlet gas pressure (two-stage gas valve)
Measure gas inlet pressure with a calibrated U-tube or digital manometer on the inlet pressure boss. - Check supply duct static at the coil test hole
Supply static is read between the furnace and cooling coil; return static is read between the filter and blower. - Checking venting after removing an old furnace
When an existing furnace is taken out of a shared venting system, the remaining appliances may no longer vent properly. Test the remaining appliances - Choosing a condensate disposal method
Three disposal options are allowed: direct to an external drain, through a neutralizer then to the drain, or through a condensate pump then to a suita - Choosing a vent terminal location
Pick a termination spot where flue gas cannot pool or get pulled back into the combustion air intake, and where condensate or frost will not cause dam - Choosing the furnace location and airflow orientation
Locate the furnace centrally to the air distribution system and keep return grilles and registers open. Ducts cannot attach to the back of the furnace - Choosing the installation location
Pick a location with enough clearance, venting, drainage, and access to gas and electrical supplies. Do not install outdoors, and do not install in an - Clean the secondary heat exchanger
The secondary heat exchanger sits directly above the blower assembly and can collect dust. Dust on warm surfaces is kept to a minimum because it can b - Combustible clearances and floor mounting
Furnace may only sit on a wood floor. Keep the area clear of combustibles and storage. Service clearance overrides the combustible clearance. - Combustion air and contamination checks
Improper or insufficient combustion air can expose occupants to combustion products including carbon monoxide. Keep the furnace away from contaminated - Combustion air in a confined space with indoor air (Case 2)
Confined space needs two openings, one within 12 in of the ceiling and one within 12 in of the floor. - Combustion air in an unconfined space (Case 1)
Unconfined space needs at least 50 cubic feet per 1,000 Btu/hr of all fuel burning appliances in the area. Outdoor air may still be needed in airtight - Combustion air inlet protection for non-direct vent
Protect the combustion air inlet from blockage when using indoor combustion air. - Concentric vent kit selection
Approved concentric vent termination kits for this furnace series. - Concentric vent terminal installation
A concentric kit lets one wall penetration handle both combustion air intake and exhaust. Use an approved IPEX kit and follow the kit maker instructio - Condensate drain not freezing or draining properly in attic or unconditioned space
Frozen condensate lines block the drain and shut the furnace down. - Condensate drain piping to floor drain, sump or pump
Condensate from the trap outlet must go to a floor drain, sump pit, or a condensate pump if neither is available. Any pump used must be rated for furn - Condensate drain setup and trap mounting
The furnace can make up to about 4-1/2 lb of water per hour (about 2 imperial quarts, 2-1/2 US quarts or 2-1/4 liters). Provide a drain path, and prot - Connecting the condensate drain
Furnace condensate is acidic (pH about 3 to 5). Dispose of it according to local codes. Choose one of three disposal options and follow the drain rule - Connecting the non-direct vent combustion air inlet
When indoor air or non-direct vent is used, the combustion air inlet must be protected from blockage. - Connecting the supplied drain hoses to the trap
Two hoses connect the front manifold cover and the inducer to the trap assembly. The larger tube goes to the manifold, the smaller tube goes to the in - Convert condensate drain and water connections from left to right
The furnace ships with the auto water fill connection and junction box on the right side, with the condensate hose set for left side installs. Use thi - Convert the drain trap assembly for right-side installation
Changes the condensate drain trap, overflow and grommet layout from the left-side arrangement to the right-side arrangement. - Converting natural gas to LP
The furnace is built for natural gas and can be converted to LP with the factory conversion kit. The kit includes instructions, orifices for all model - Cut side return opening and connect supply duct
Guide dimples mark the side return opening. Do not cut larger than marked. An undersized opening reduces airflow. - Direct vent wind pressure zone check
Requirement for vent and combustion air placement on direct vent installations. - Downflow vent and drain layout options
Downflow furnaces can use a left or right vent with the drain on the opposite side, internal or external. Air intake and exhaust cannot be on the top - Draining the condensate trap
Drain and remove the condensate trap for service. Step 1 is on the previous page (143) and is not included here. - Draining the condensate trap (horizontal models)
Remove the condensate trap to empty it, then reinstall it securely. - Draining the water tank and condensate trap (upflow and downflow models)
Use this to empty the water side when the furnace will sit unused for a long time. Damage from freezing is not covered by the warranty. - Duct sizing and return air limits
Ducts must match the furnace CFM and external static rating. Return air must not be restricted or taken from a small enclosed space. - Ductwork installation steps
Ductwork layout and return air connection for upflow, horizontal and downflow orientations. - Erratic operation from vapor lock in drain line
The drain configuration needs a vent. Less than a one inch rise along the horizontal drain run can form a vapor lock, which stops condensate from drai - Evaporator coil installation and protecting the hydronic coil
Install the coil upstream of the cooling unit and keep fasteners out of the hydronic coil area. - Extreme cold climate venting
Requirement for periscope venting where extreme cold is expected. - Freeze protection for condensate drain
The trap and drain line should stay inside conditioned space. Where temperatures can reach 32 F (0 C), protect the trap and drain line. A rated self-r - Freeze protection for furnace, trap and drain
Where the furnace may reach near 32°F (0°C), such as an alcove or attic, insulate the drain trap, drain pipe and supply water line. Exposed drain pipi - Furnace does not light after first start or gas line work
Air trapped in the gas supply line can stop the furnace from igniting during the first trial ignition after installation or after gas line work. - Furnace operated with front cover or access doors off
Running the furnace with covers or doors open can release exhaust gas or CO into the room and cause fire or CO poisoning. - Furnace power connection and grounding
The junction box is in the blower compartment. Connect the house wiring to the furnace leads, and make sure the cabinet is continuously grounded. - Furnace run without air filter
Running without a filter lets dust clog the heat exchanger and lowers furnace performance. - Furnace runs longer than the thermostat set point (heating)
Heating runs long when the furnace RA set temperature is below the thermostat set point. - Furnace that has been under water
A flood-damaged furnace is dangerous and must not be used. - Gas piping installation
Gas piping must follow NFPA 54/ANSI Z223.1 in the US or CAN/CSA-B149.1 and 2 in Canada, plus local codes. The gas pipe into the furnace side panel mus - Gas regulator arrangements for LP supply
The manual shows a single regulator system (12 in WC) and a two stage system with a high pressure and a low pressure regulator. The two stage system i - Gas smell near the furnace
Suspected gas leak. Treat as an emergency and do not operate any appliance or electrical switch in the building. - Gas supply connection and leak check
Gas connections must be made by a licensed professional. Size the line and check for leaks before the furnace is put into service. - Gas type and high altitude conversion procedure
Converting the furnace to propane or to high altitude natural gas. Use only the Navien conversion kit for the job. Tools needed: Phillips and flathead - Horizontal exhaust and combustion air termination layout
Terminal geometry for horizontal venting to keep flue gases from recirculating into the intake. - Horizontal vent and drain layout options
Horizontal furnaces can exit the vent on the right or left panel, or through the top panel, with the drain on the matching side. Figures 17 and 18 sho - Install the condensate neutralizer kit
Use the Navien neutralizer kit when condensate goes to a drain through neutralizing media, which raises the pH and protects the drain system and publi - Installation checklist: airflow and temperature records
Readings to record at commissioning. Record duct static pressure and air temperature rise or drop at each operating point. - Installation checklist: DIP switches and owner handover
Final checks on switch settings and customer handover. - Installation checklist: location, clearances and gas supply
Confirm before commissioning that the location and gas supply are correct. Each item must be a yes before the install is complete. - Installation checklist: power supply and condensate drain
Electrical and drain checks to complete before startup. - Installation checklist: venting
Vent checks for the furnace exhaust and intake piping. - Installing the combustion air inlet pipe drain
Where moisture can enter the combustion air inlet pipe, condensation can form and drip inside the furnace. A short horizontal or vertical section of p - Installing the condensate trap (horizontal models)
Horizontal models use a different hose route, with the trap connected through the side hole and secured with an overflow adapter and a hose bracket. D - Installing the condensate trap (upflow and downflow models)
The trap mounts on the side of the furnace and can go on the right or left. The hose and overflow hose are marked right or left type. Water tank plugs - Installing the intake and exhaust air collars
Remove the upper front cover and attach the intake and exhaust collars with the VID sensor cable routed through the cabinet. The exhaust collar connec - Installing the pressure relief valve
Install a 30 psi maximum pressure relief valve on the 3/4 in adapter on the upper cover. The valve must be ASME certified and installed only by a lice - Installing the vent drain option
Use when vent runs through an unconditioned space like an attic or crawl space to stop condensate building up in the inducer housing. - Leak testing gas piping
Gas piping that has not been pressure tested, such as from the manual shut-off valve to the furnace gas valve, must be leak tested. New installations - Leak testing new gas piping
Leak test all new gas piping and any section not yet pressure tested, such as from the manual shut-off valve to the furnace gas valve. Pressure test p - Measure inlet gas pressure
Licensed professional only. Furnace must have enough inlet gas pressure to run. Steps 2 to 7 are not on these pages. - Measure total external static pressure
Total external static is the return reading (negative) plus the supply reading (positive), with clean filters in place. - Never install a twin-pipe low profile termination with exhaust nearest ground
Only certain twin pipe orientations are allowed for low profile terminations. - Non-direct vent (single pipe) back-draft risk
If the installation location can go into negative pressure, cold air can be drawn back through the heat exchanger, which can freeze it and cause a mal - Non-direct vent termination cap and intake setup
For non-direct venting, the intake air duct gets a termination end cap. The cap is not glued so it can be removed for cleaning. - Outdoor air from attic or crawl space (Case 3) install notes
Attic air is used only if the attic is adequately vented and the opening is above the insulation. - Prepare vent pipe and fittings
Clean and prepare pipe so debris cannot block the exhaust, combustion air inlet or condensate drain. - Preparing the vent and drain option
Choose the vent and drain option first, then prepare the inducer, vent and intake connections and the trap location. - Propane gas supply and piping
Propane pressure and piping checks from the manual. - Protecting the furnace from freeze damage during outages or long shutdown
Power failures in cold weather stop the freeze prevention system, which can freeze the heat exchanger. - Relocating the junction box to the opposite side panel
The furnace ships with the junction box set for right side line voltage entry. Move it to the other side before making line connections there. - Return air ductwork sealing and joist space safety
Poor sealing or gas piping in return joist spaces can pull combustion products into the living space. - Rotating the inducer and mounting pressure switches
Rotate the inducer to suit the chosen flue orientation, then reinstall the pressure switches and hoses so condensate cannot reach the sensing hose. - Routine homeowner checks
Quick inspection to do each time the air filter is checked. Venting and terminals must be kept clear and sealed. - Routine maintenance checklist
Minimum maintenance for the NPF hydro-furnace, done by a qualified service provider where noted. - Select and install return filter
Filters are not supplied with the furnace and must be field provided, sized and installed external to the furnace. - Selecting a vent type (direct vent preferred)
The furnace is a Category IV appliance set at the factory for direct vent (sealed combustion). Direct vent is preferred so combustion air stays clean - Selecting approved vent pipe materials
Venting rules differ in the US and Canada. Use approved materials only and never mix pipe types, as this can leak flue gas into the living space and v - Set manifold gas pressure (two-stage gas valve)
Set low-fire and high-fire manifold pressure with a manometer on the outlet pressure boss. Always follow the values on the rating plate. - Set up a 24 V 1-stage or 2-stage heating thermostat
Single-stage or two-stage heating thermostats must be set up on the front control panel. Thermostat wiring enters through the holes in the blower comp - Set up a dual fuel heat pump balance point
Dual fuel operation uses an outdoor temperature sensor. The balance point is the outdoor temperature at which the system switches from heat pump heat - Setting the furnace on a level base and combustible surfaces
The furnace must sit level so condensate drains properly. Do not install it directly on carpet or other combustible material; wood is the only combust - Shut off gas to the furnace
Use before service or in an emergency such as overheating or a gas valve that will not shut off. - Slow or debris-filled condensate drain
Water should flow easily through the condensate drain line. Blocked drainage can back condensate into the heat exchanger and cause nuisance pressure s - Spacing vent terminations for multiple furnaces
Each furnace needs its own dedicated combustion air intake and exhaust. Common venting is not allowed. - Supply air temperature sensor fault (open or short)
When the supply air sensor reads open or short, the furnace drops to Emergency heat mode and keeps heating. - Support and drainage of horizontally installed furnace
The furnace must drain correctly when installed on its side, so the full length must be supported. - Thermostat placement
Mount the thermostat where it sees average room temperature and natural air circulation. - Upflow vent and drain layout options
Upflow furnaces can exit the vent at the top or left side, with the condensate drain on the left or right and either internal or external trap mountin - Upflow vent layout options (left and right vent)
Left and right vent exits on an upflow furnace can be paired with left or right drain sides and internal or external trap mounting. The figure shows e - Using the furnace as a construction site heater
The furnace may be used during construction only if all the listed conditions are met. - Vent location precautions and condensate protection
Avoid locations where flue condensate, freezing or recirculation can cause damage or problems. - Vent pipe check if the furnace will not start after vent work
Use this check when the furnace will not run after the vent is connected, or when the vent detector reports a fault. - Vent sizing and length checks
Confirm the vent system is within length limits before installation. - Vent termination clearances in Canada
Minimum distances for the vent exhaust terminal in Canada. - Vent termination clearances in the United States
Minimum distances for the vent exhaust terminal in the United States. - Vent termination placement
The termination must be at least 12 in (300 mm) above ground, at least 12 in above the highest expected snow level, or meet local code, whichever is g - Venting blocked or furnace run without proper venting
Blocked vent terminals or unsealed wall openings can allow combustion products into the building and cause CO poisoning. - Venting method overview (Category IV FSP)
This furnace is certified as a Category IV Type FSP furnace for non-direct and direct vent installations. - Vertical exhaust and combustion air termination layout
Terminal layout for vertical venting through a roof. - Wire a dehumidistat to the sub controller
Dehumidistat must run on 24 VAC and use a switch that opens when humidity rises. During a combined cooling and dehumidification call the blower runs a - Yellow or lazy burner flames
Flames should be clean and blue. A little orange is usually dust burning and is not a concern. Yellow flames lead to soot-up.
Rheem (72)
- Annual and start-of-season inspection
Recommended inspections by a qualified installer, service agency, or gas supplier. Do the flame, flue, and condensate checks at the start of the heati - Blower codes 66, 61 and 60 - what to look for
Quick sorting of the three ECM motor codes on the R96V control. - Blower does not start after burners light
The burners light and run but the blower doesn't come on, or it comes on late. On this furnace the blower should start on heat speed about 20 seconds - Burners go out before the heat call ends / short cycling
Main burners do not stay lit until the thermostat is satisfied, or the room temperature is not held near setpoint. - Canada only: derate high altitude by lowering manifold pressure
In Canada, unless local codes mandate an orifice change, altitude derate can be done by lowering manifold pressure instead. The table values assume 10 - Cement PVC vent joints
Method for joining PVC vent pipe and fittings with cleaner-primer and medium-body solvent cement. - Check airflow with a temperature rise measurement
Use this check to confirm airflow over the heat exchanger. Temperature rise should sit near the middle of the range on the furnace nameplate. Too high - Check vent length with elbows
Every vent system has a maximum equivalent length, and fittings count as extra length. This is a worked example for the 60 KBTU/H direct vent model us - Checking furnace input rate
Clocking the gas meter to confirm the Rheem 96V/96MDV isn't over-fired. Input must never go above the rating plate. - Clearing lockouts and hard lockout conditions
All lockouts clear immediately once the original fault is cleared and power is cycled off and on. Soft lockouts also clear if the heat call is cycled - Communicating system not found / no communication
On a Rheem/Ruud RGPE or RGLE communicating furnace, the thermostat should show SEARCHING, then FURNACE FOUND and AIR CONDITIONER or HEAT PUMP FOUND wi - Condensate drain checks before startup
A condensing furnace makes water, and that water has to leave the house, so before you fire it for the first time, go over the drain and trap. This is - Direct vent termination clearances (key limits)
Clearances come from Figure 32 and its footnotes. The figure text is jumbled in the source, so verify every value against the full figure before insta - Direct vent: alternate horizontal termination (Options 4 and 5)
Alternate horizontal termination with the intake and exhaust spaced as shown. Option A requires a trap in the combustion air pipe. Option B does not. - Direct vent: angled horizontal terminations (22° or 45°)
Optional termination angles apply only to Options 4 and 5. Do not use angled terminations with any other option. Angled terminations cannot be used on - Direct vent: concentric vent kits RXGY-E02A (2 in) and RXGY-E03A (3 in)
Concentric kits for vertical or horizontal intake and vent runs through a roof or sidewall. The 3 in kit needs a 5 in diameter hole. The 2 in kit need - Direct vent: sidewall termination kits RXGY-G02 (2 in) and RXGY-G01 (3 in)
Horizontal venting only. Use RXGY-G02 for 2 in pipe or RXGY-G01 for 3 in pipe. The kit can be used with either direct or non-direct vent. Do not insta - Direct vent: standard horizontal termination (Options 2 and 3)
Standard horizontal termination. Intake and exhaust are sized and spaced as shown. The trap is only needed for Option B. Couplings are required on the - Direct vent: standard vertical termination (Option 1)
Standard vertical direct vent termination, Option 1 in the Rheem 96V/96MDV instructions. The big thing is keeping the intake and the vent apart so the - Direct vent: two-pipe layout and intake separation
Direct vent. Two pipes. One brings combustion air in, one sends flue gas out. Exhaust has to sit at least 12 in above the intake on vertical runs, or - ECM blower does not start on heat
RGPE/RGLE: ECM blower not starting on heat. It should come on at high heat speed 15-20 seconds after the burners light. Rheem/Ruud (-)GPE and (-)GLE 2 - ECM blower does not start on high heat after burners light
Use this check when the burners light but the ECM blower does not start roughly 15 to 20 seconds later on high heat. Turn the power off before touchin - ECM blower will not run - power and communication checks (code 68)
The communicating blower motor does not start on a heat, cool or fan call and the control shows 68. - Example: checking orifice size at high altitude (natural gas)
Worked example of orifice sizing for natural gas at altitude, using a 900 BTU/ft3 regional gas. These numbers are for the example only. Do not reuse t - Field conversion: downflow with right vent (non-zero clearance)
Converts the furnace to downflow with right vent, non-zero clearance. Uses the factory-installed trap, hoses and drain parts as shown. Parts come from - Field conversion: downflow zero-clearance
Converts the furnace to downflow zero-clearance. Requires parts from the parts bag, conversion kit RXGY-CK and zero-clearance kit RXGY-ZK. Tools inclu - Field conversion: horizontal right with right vent
Field conversion of the furnace to horizontal right airflow with the vent on the right. Steps 1 and 2 are done with the furnace in as-shipped conditio - Field conversion: horizontal right with vertical vent
Field conversion to horizontal right airflow with a vertical vent. Steps 1 and 2 are done with the furnace in as-shipped condition. Parts come from th - Field conversion: upflow with left side vent
Converts the furnace from the as-shipped upflow configuration to upflow with left side vent. Tools: electric drill, 1/8" drill bit, pliers, flat-head - Final review after a horizontal conversion
Last pass on a Rheem 96V/96MDV horizontal conversion, before you leave the job. Tick every item on the printed checklist. Skip one and you're back for - Five-minute lockout (low pressure switch fails to close)
A five-minute soft lockout starts if the low pressure switch does not close within 60 seconds of continuous inducer operation at the start of a heat c - Furnace does not light or goes into lockout
Use the 2-stage IFC troubleshooting chart when the furnace will not ignite or keeps locking out. - Furnace no heat - sequence troubleshooting
Step through the normal heat sequence: pressure switch check, 30-second prepurge, 8-second ignition trial on low fire, blower on about 20 seconds afte - Furnace short cycles or does not hold setpoint
Rheem 802PA furnaces and matching 80MDP models: heat cycles end early or the room temperature drifts away from the setpoint. Applies to (-)802PA050314 - Gas supply piping arrangement at the furnace
Gas supply piping at the Rheem 96V/96MDV, per the gas piping figure. Each branch gets a manual shut-off, a union and a drip leg. - Gas supply piping layout
Gas piping has to be sized so the valve gets enough pressure when everything is running, and set up so the valve can be serviced later. Think about th - Gas valve does not shut off when heat call ends
If the burners stay lit after the thermostat is turned off, treat it as an emergency until the gas is shut off. Most of the time, in my experience, th - Gather parts and tools before a horizontal field conversion
Check the parts list for the conversion you are doing before you start. Some parts come from the parts bag shipped with the unit and some come from co - Heat call troubleshooting walk-through (two-stage communicating IFC)
Order of checks from the factory diagnostic chart when a heat call does not end in high-fire heat. - Horizontal left with left vent: trap, plugs and caps
These are the opening changes for a left-vent horizontal conversion on the 96V. Make sure the furnace is disconnected from power and gas before you st - Horizontal left/right with right vent: remove elbow, trap and factory plugs
First round of work when converting a 96V to horizontal with the vent on the right. Pull parts, keep some, toss some. Keep your pile organized. Elbow - Horizontal vent slope, support and freeze protection
Installation rules for horizontal and external vent and combustion air piping. - Indoor blower does not start after burners light
On these Rheem 90 Plus condensing furnaces the burners light normally, but about 20 seconds later the main blower doesn't come on at heat speed. The f - Inducer (draft motor) does not start on heat call
On the Rheem/Ruud (-)95P series 95% single-stage condensing furnace (R95PA), there is a call for heat but the inducer never starts. Take it slowly. A - Inducer does not run / does not run on low speed
On the Rheem/Ruud (-)GPE upflow/horizontal and (-)GLE downflow 2-stage 80+ communicating gas furnaces (RGPE/RGLE), the inducer will not run, or will n - Inducer runs 60 s then shuts off for 5 minutes, or runs continuously
Rheem 90 Plus condensing furnace. Inducer runs 60 s, shuts off for 5 minutes, or never stops, and the furnace never lights. Classic proving problem. S - Inducer runs 60 seconds then off for 5 minutes
R95P (Rheem/Ruud (-)95P, 95% single-stage). Inducer runs 60 seconds, drops out for 5 minutes. Pressure switch not proving. Look at the vent and the sw - Install intake coupling, air diffuser, intake pipe and flue pipe (steps 6-7)
Install the intake and flue hardware on the blower shelf and secure the pipe collars. The air diffuser can fall out of the coupling, so the manual all - Install solid metal base pan for upflow side return
If you're setting up a Rheem 96V/96MDV upflow with a side air return, the solid metal base pan has to go in. Skip it and combustion products can get i - Installation checklist (commissioning record)
Record these values on the checklist sheet for service and warranty records. Items cover gas supply, electrical, clearances, static pressure, temperat - Intake diffuser, condensate trap and drain plug changes (steps 3-5)
Relocate drain and vent parts on the collector box and jacket, then install the condensate trap and the intake air diffuser. - LP conversion and orifice spud change
To run this furnace on propane, the gas valve has to be converted by replacing the regulator springs with the kit springs, and the orifice spuds chang - LP gas at high altitude: select orifice from drill size table
Propane has a consistent heating value, so picking an orifice at altitude is more of a table lookup than a calculation. The catch, which people trip o - Measuring and adjusting manifold gas pressure
Manifold pressure is the pressure at the gas valve outlet that actually feeds the burners. I check it with a heat call active, and I set it on high fi - Measuring supply gas pressure
Supply, or inlet, gas pressure is measured at the gas valve with a calibrated manometer. Do it with the furnace and all the other gas appliances on th - Moving the line voltage junction box to the other side
Only do this with the furnace disconnected from line voltage. The door switch moves with the junction box. - Multiventing two or more direct-vent furnaces
Each furnace must have its own individual vent. Common venting is not allowed. Spacing rules depend on how many terminations are installed. - Natural gas at high altitude: derate and orifice check
No high altitude pressure switch change is needed. The input must be derated 4 percent per 1,000 ft above 2,000 ft. Factory orifices are sized for a s - No heat - inducer (IDM) does not start
POWER LED on, thermostat calling, but the induced draft motor never starts. - No heat - POWER LED off
When a Rheem 90 Plus condensing furnace (the (-)GRC/(-)GTC and 90RJ/90TJ) is dead on a heat call and the POWER LED on the integrated furnace control i - Non-direct vent: alternate horizontal termination
This is the alternate horizontal terminal for a non-direct vent install, where the furnace draws combustion air from the room and only the exhaust goe - Non-direct vent: RXGY-G02 sidewall vent kit
On the Rheem 96V/96MDV, the RXGY-G02 sidewall vent kit works for non-direct vent as well as direct vent installs. The full instructions live in the di - One-hour lockout causes
A one-hour soft lockout starts when any of these occur: flame not detected after four ignition trials; flame lost five times in one heat call; undesir - Post-conversion checklist
This is the walk-around before you close up a field conversion on a Rheem 96V or 96MDV. Most call-backs I see after conversions are a kinked hose or a - Read target airflow from the CFM LED
RGRM/RGTM controls have a CFM LED that blinks out the airflow the blower is aiming for. Use it as a rough check of blower setup, not as a measurement. - Replacing the furnace control (memory card)
The memory card on the original furnace control holds critical model data. It stays with the furnace, tethered by the plastic wire tie, and it moves t - Rotate the furnace 180 and prepare the blower shelf and jacket (downflow steps 5-7)
Steps shown with the furnace in downflow orientation. The junction box and door switch must be moved for the flue pipe, so follow the electrical wirin - Setting gas manifold pressure
You set manifold pressure after you have confirmed that supply pressure is within limits. Do not adjust the regulator on a bad supply, or you will cha - Sidewall direct-vent termination kit installation
Kit RXGY-G02 is for a 2-pipe system and RXGY-G01 for a 3-pipe system. Horizontal only, may be used as non-direct or direct vent. Dimensions between in - Thermostat does not hold room temperature
Rheem/Ruud (-)95P series furnace runs, but the room never gets near the setpoint. Check the thermostat's surroundings before the furnace itself. - Upflow with vertical vent: condensate drain and intake conversion
Converts the furnace for upflow with vertical vent using only parts from the parts bag. Install the intake coupling, choose the right or left drain si - Worked example: natural gas orifice at 5,000 and 8,000 ft
A worked example from the manual showing how the orifice drops as altitude rises. It uses a regional natural gas value of 900 BTU per cubic ft and 14,
Trane (63)
- Abnormal conditions and protection
Summary of how the furnace responds to abnormal conditions. - Adjust gas valve manifold pressure
Set manifold pressure with a gauge on the White-Rodgers 36G or 36J valve. - Air for combustion and ventilation in non-direct vent installs
On non-direct vent UH1/DH1 installs the furnace draws combustion air from the room, so the air openings have to stay open and clear. Starving a furnac - Airflow adjustment check
Before changing airflow on an AUH1B furnace, check the air temperatures across the heat exchanger first. Airflow is changed at the blower motor speed - Airflow and temperature rise check
At startup on this Trane, confirm airflow by checking inlet and outlet air temperatures against the furnace rating plate. Do it with the furnace stabi - Blower door switch shutdown
Some units have a blower door switch that cuts power to the blower and gas valve when the door is removed. - Bottom return filter rack installation (upflow)
The BAYRACK960 is an optional filter rack that lets you put the filter in the bottom return of an upflow furnace. It is a simple install, but go slow, - Carbon monoxide detectors and signage for Massachusetts side-wall venting
Side-wall horizontal venting where the exhaust terminal is under 7 ft above grade needs CO detectors and signage. - Choose combustion air method: confined or unconfined space
Before anyone sizes combustion air openings, you have to decide whether the furnace sits in a confined or unconfined space. I see this missed on basem - Combustion and input check
Combustion and input check means finding out how much gas the furnace is actually burning. You do it by timing the gas meter with only the furnace run - Condensate drain for horizontal installations
Horizontal installs are left-side drain only, and the trap has to move outside the cabinet. Auxiliary drain pan goes under any horizontal evaporator o - Condensate drain for vertical upflow and downflow installations
Upflow and downflow units use different drain tubing and trap routing, and the drain should have a drain pan under it. - Downflow furnace on combustible floor (subbase)
DH1 downflow on a combustible floor. Can't sit it right on carpet, tile or any combustible flooring. Wood flooring is the exception. Use the subbase. - Downward venting
Downward venting is when the vent has to go down before it goes out, usually through a basement wall or floor. It works, but it is limited in length, - Duct connection and return air
Duct layout and return air requirements for the furnace. - Filter clip and rack use by cabinet width
Table 6 in the Trane guide sorts out which return positions take the standard filter rack and which need the alternate clips. It trips people up becau - Filter placement for upflow furnace in horizontal configuration
Before you lay an upflow Trane furnace on its side, think about the filter first. The manual says a filter must never sit inside or outside the cabine - Fit the return air filter
The return air filter that comes with the Trane may need trimming, depending on where your return ends up. It is an easy job but do it right: measure - Flame rollout protection control open
Flames are not drawn properly into the heat exchanger and the flame rollout control opens, shutting the unit off. - Freeze protection and drain pipe sizing
Frozen condensate lines block drains and shut the furnace down. Freeze protection and pipe size rules apply. - Freeze protection for vent pipe
Vent pipe that runs through spaces below freezing has to be insulated, or condensate in the pipe can freeze and block the vent. Domestic water pipes t - Freeze protection for vent pipe in unheated spaces
Vent pipe through unheated space gets insulation. - Furnace in attic or crawl space (horizontal)
Placement rules for a horizontal furnace in an attic or crawl space. Mostly about clearances, access and keeping the unit dry and supported. - Furnace location and clearance check before setting in place
Confirm the site meets the basic location requirements before the furnace is moved into position. - Gas piping installation
Gas piping to the furnace is simple once you know the rules. Upflow units ship set up for left-side gas piping, and there is a right-side knockout if - Gas supply pressure testing
Gas line pressure testing and the furnace valve: protect the valve from test pressure above 1/2 psig. Higher than that damages the gas valve. - General venting requirements
Furnaces are induced draft, Category IV, positive vent pressure. Vent must be gas tight and water tight. - Heating cycles too fast or too slow
The room temperature swings widely in heating. - Heating will not come on
Heat is called for but the system does not start. - High altitude derate and orifice change
Input is based on sea level and is only changed above 2,000 ft. - Horizontal installation support and drain
When you lay a furnace on its side, the coil and the furnace both need real support and a way to get rid of water. People forget the coil drain, and t - Horizontal vent termination through wall
On a horizontal wall termination, the thing I find wrong most often is a vent set too close to grade. Snow drifts, mulch or a flower bed will bury it - Horizontal venting through a wall
Wall-vent terminations must sit clear of expected snow and must not sit where condensate or staining can cause trouble. Vent pipe must slope upward so - Install alternate upflow filter clip / bracket kit (KIT09224)
KIT09224, alternate upflow filter clips. Side return uses the cabinet dimples, bottom return has holes drilled already. Leaf spring clip goes at the r - Install filter rack for side return on upflow furnace
This is the checklist for fitting a left or right side return filter rack (BAYRACK960) on an upflow furnace. What I usually find when this goes wrong - Insufficient heating – blower runs continuously
The blower runs all the time but the space is not getting enough heat. - Limit switch check at startup
Verify the high limit shuts off burners when the furnace overheats. Installer check at startup. Watch it the whole time. Stay at the furnace and shut - Limit switch check during startup
The high limit has to open and shut the burners off at the rated outlet temperature. This is an installer's check at startup, and I always do it, beca - Measure manifold pressure from the burner box
Manifold pressure on this Trane has to be referenced to the burner box, not read against room air at the valve outlet. Gas work, so a licensed technic - No heat
Heat does not run, or runs only intermittently. - No heat – vent motor running
The vent (inducer) motor runs but the unit produces no heat. - No heating – blower does not operate
The unit does not heat and the blower does not run. - Oil furnace wiring: external relay and bonnet thermostat
Oil furnace applications need an external relay. Dual fuel oil applications also need a bonnet thermostat. - Pressure switch prevents operation – flue blocked
The unit cannot exhaust combustion products, so the pressure switch safety device stops operation. - PVC solvent cement joint procedure
Cure time varies with fit, temperature and humidity. - Reading and clearing fault history - Trane S-Series IFC
How to pull up stored faults, wipe them and reset the furnace control to factory values with the Menu and Option buttons. - Resize remaining vent when a furnace is removed from a shared vent
Pulling a furnace out of a shared vent leaves the other gas appliances on a vent that was sized for more input than they put out. I have found plenty - Roof venting
Roof vent. Keep a set height over snow. Seal the roof penetration. Leaks here mean wet ceilings. Too tall and the pipe gets exposed to wind and frost. - Side return filter rack installation (upflow, left or right)
BAYRACK960 filter rack into a side return on an upflow furnace. - Stainless steel vent fitting installation
Type 29-4C stainless fittings are required for masonry chimney and some roof venting. Orientation and sealing matter, because leaks put flue gas into - Start-of-season inspection checklist
Qualified service agency checks the installation before each heating season. Check venting, return duct, base support, burner flame, and combustion an - Temporary heating during building construction
I see it all the time, a builder wants the new furnace running while drywall dust is still flying. The manufacturer allows it only if every listed con - Twinning furnaces
Twinned Trane furnaces share a duct system, so they have to be matched and see equal resistance. Before wiring anything, confirm both units are identi - Two pipe venting configurations (same pressure zone)
Two pipe venting on the Trane. The manual only shows its configurations for the case where both terminations sit in the same pressure zone. Out of tha - Unit cycles on the high-limit control
The automatic reset safety limit control shuts off heat to prevent overheating. Poor airflow can make the unit cycle on and off as the limit trips and - Unusual noise
The unit makes an unusual noise during operation. - Upflow furnace with cased coil attachment
Before you set a factory cased coil on a Trane UH1 upflow furnace, read the installer's guide and gather the standoffs and screws that came with the c - Vent and inlet air connection and pipe support
Pipe joints have to be fastened and sealed so combustion products stay out of the building. Think of it as two jobs. The inlet is a friction fit seale - Vent and inlet terminal spacing
Terminal spacing for the vent and inlet is given in the venting figures. The numbers for each dimension depend on which termination you are building, - Venting system check before placing an appliance back in service
Used when other gas appliances share the venting system. Test each appliance one at a time while the others are off. - Venting through a ceiling
When a furnace vent passes through a ceiling, you need a proper firestop and a sealed support flange. I have seen vents just poked through a hole with - Venting through a masonry chimney
Venting a condensing furnace through a masonry chimney is only allowed under specific conditions, and the chimney must never be one that serves a soli - Wall vent clearances and shielding
Clearances depend on wall construction and vent material. Combustible walls need an air space and a shield, and wall-vent flue gas can damage nearby m
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.