All brands · Furnace troubleshooting

Low draft / blowback

What is going on

Low draft or blowback means the flue gases are not leaving the building the way they should, and that can put carbon monoxide into the living space. Confirm a working CO alarm is in the home before you do anything else, and shut the appliance down if you smell exhaust or see spillage. A licensed technician should sort out the venting.

Likely causes

  • Shared flue overloaded by other appliances
  • Chimney obstruction such as soot, a nest or loose bricks
  • Tight house, with not enough air for combustion and venting

Check in this order

  1. Shut the appliance off if there is spillage and ventilate the space before any testing
  2. Measure draft at the breech and compare against the manual
  3. Inspect the chimney and flue for blockage and have it cleaned or repaired
  4. Check what else is connected to the flue and whether the flue is sized for it
  5. Add an outdoor combustion air supply if the house is tight
  6. Retest draft and CO with the exhaust fans and dryer running to check for house depressurization

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.