Blower runs, not enough heat
What is going on
The blower is moving air but it feels cool at the registers. On an electric furnace that means some or all of the heating elements are not energizing. Electric heat draws large current at line voltage, so shut off the breaker and confirm with a meter before you open the panel, and leave live element testing to someone qualified.
Likely causes
- Dirty filter restricting airflow
- Low supply voltage
- Only some elements energized, due to an open fuse or breaker on an element, a burned-out element, or a sequencer not closing
- Second stage of the thermostat not working
Check in this order
- Turn off the breaker and confirm zero volts before removing any cover
- Check the filter and replace it if loaded
- Check each element's fuse or breaker for an open
- Check each element for continuity with power off
- With power restored by a qualified person, confirm the sequencers close in order after the call for heat
- Meter line voltage at the unit under load
- Check the thermostat's second stage call and wiring
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.