Blowing cold air

What is going on

The blower runs but the air coming out of the registers is cold.

Likely causes

  • Thermostat fan set to On instead of Auto
  • Burner not lighting or locking out
  • Limit or pressure switch open while the blower keeps running
  • Gas supply problem

Check in this order

  1. Set the thermostat fan to Auto
  2. Check the control board LED for a lockout or limit code
  3. Confirm gas supply and that the burners light
  4. Check the condensate trap and pressure switch tubing
  5. Verify temperature rise once the burner runs

Applies to: Gas furnaces

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.