Blowing cold air

What is going on

The blower is running, but the air at the registers feels cold. Before opening anything up, confirm whether the burners are actually firing, because a cold-air complaint on a gas furnace is often a heat-call problem rather than a failed part. Gas and line voltage are involved here, so anything past the basic checks belongs to a licensed technician.

Likely causes

  • Thermostat fan switch left on On instead of Auto, so the blower runs between heat cycles
  • Burner not lighting, or the control locked out after failed ignition
  • Limit or pressure switch open while the blower keeps running
  • Gas supply interrupted at the valve, meter or line

Check in this order

  1. Set the thermostat fan to Auto and call for heat, then listen for the inducer and watch for the burners to light
  2. Look at the control board LED and compare the flash code to the legend on the door for a lockout or limit fault
  3. Confirm the gas shut-off is open and that the burners ignite and stay lit; do not force the gas valve or bypass any switch
  4. Check the condensate trap and the pressure switch tubing for water or blockage on a condensing unit
  5. Once the burners hold, measure the temperature rise across the furnace and compare it to the range on the rating plate

Applies to: Gas furnaces

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.