Board shows "flame sensed with no call for heat"
What is going on
When the board throws a flame sensed with no call for heat code, I think gas valve first. The control is seeing flame when the thermostat isn't asking for any, and the usual real-world reason is a valve that leaks by or sticks open. Take it seriously, because gas may be getting to the burners when it shouldn't.
Likely causes
- Gas valve leaking by or stuck open
- Flame sense error that clears on a power cycle
- Flame sensor or board fault giving a false reading
Check in this order
- Look in the burner compartment for flame with the stat satisfied
- If flame is present, shut off the gas at the manual valve and power down
- Cycle 120 V power to the furnace and see if the code returns
- If the code returns or flame is visible, call a licensed tech to replace the gas valve
- Do not keep running a furnace with a suspect gas valve
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.