All brands · Furnace troubleshooting
Cold air blast at start / blower never stops
What is going on
A cold blast at the start of a cycle, or a blower that never stops, is a fan control problem. Look at what the fan switch or the delay settings are set to before you assume the part is bad. Switch the power off before opening the control compartment.
Likely causes
- Fan switch set point or time delay set wrong, the fan typically comes on at about 140°F and goes off near 90°F
- DIP switch or jumper delay settings changed
Check in this order
- Turn power off before opening the furnace
- Check the fan on and off set points against the manual
- For boards, check the DIP switch or jumper delay settings
- Set the on delay and off delay per the manual
- Watch a full cycle and confirm the blower starts warm and stops properly
- Replace the fan switch or board if the delays won't hold
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.