All brands · Furnace troubleshooting

Combustion gas / odour in house, flu-like symptoms

What is going on

If the house smells like exhaust or people are getting headaches, nausea and flu-like symptoms with the heat on, treat it as carbon monoxide until proven otherwise. Open windows, get everyone outside and shut the furnace down. Don't wait to see if it clears up.

Likely causes

  • CO from a cracked heat exchanger
  • Combustion gas spilling out of the draft hood or vent
  • Blocked vent or flue

Check in this order

  1. Get everyone out and ventilate
  2. Shut down the furnace at the switch and the gas valve
  3. Test for CO with a calibrated meter
  4. Inspect the vent for blockage and spillage
  5. Inspect the heat exchanger for cracks
  6. Call a licensed tech and keep the furnace off until it's cleared
  7. Check CO alarms are working in the home

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.