Duct sizing and return air limits
What is going on
Ducts must match the furnace CFM and external static rating. Return air must not be restricted or taken from a small enclosed space.
Likely causes
- Closed dampers or registers.
- Undersized or poorly laid out ductwork.
- Return connected to the furnace back or to a room, closet or alcove.
Check in this order
- Design the duct system to ACCA Manual D or NFPA 90A/90B.
- Use a closed return duct system connected to the furnace.
- Do not attach ducts to the back of the furnace.
- For 1800 CFM or more, use two side returns or a side plus bottom return.
- Do not use a room, closet or alcove as a return air chamber.
Applies to: NPF700 hydro-furnace ducting
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NPF installation and operation manual, p. 51. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.