Navien · Furnace troubleshooting

Duct sizing and return air limits

NPF

What is going on

Ducts must match the furnace CFM and external static rating. Return air must not be restricted or taken from a small enclosed space.

Likely causes

  • Closed dampers or registers.
  • Undersized or poorly laid out ductwork.
  • Return connected to the furnace back or to a room, closet or alcove.

Check in this order

  1. Design the duct system to ACCA Manual D or NFPA 90A/90B.
  2. Use a closed return duct system connected to the furnace.
  3. Do not attach ducts to the back of the furnace.
  4. For 1800 CFM or more, use two side returns or a side plus bottom return.
  5. Do not use a room, closet or alcove as a return air chamber.

Applies to: NPF700 hydro-furnace ducting

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NPF installation and operation manual, p. 51. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.