Approved vent and termination components
What is going on
Approved components are listed by manufacturer. Only the part numbers shown in the manual are approved for this appliance.
Check in this order
- PVC IPEX low profile terminations (2 in #196984 / 3 in #196985 for ULC-S636; #397984 / #397985 for UL1738); PVC concentric kits (2 in and 3 in).
- Polypropylene Duravent PolyPro SW (2PPS-xxx / 3PPS-xxx), Centrotherm Innoflue SW (ISxx02xx / ISxx03xx), Z-Flex Z-DENS SW (2ZDP___).
- Stainless steel Duravent FasNSeal (FSA-PVC3, FSxxxxx03), Heat Fab Saf-T Vent EZ Seal (9301PVC, 93xx).
- Z-Flex Z Vent 2SVSTTA023 adapter, 2SVEPSCF030X straight pipe, 2SVEEWCF0390 90° and 2SVEEWCF0345 45° elbows.
- ECCO polypropylene (rigid) 2xxPPP / 3xxPPP pipe, 245PEL/287PEL and 345PEL/387PEL elbows, 203PINC increaser.
- Terminations use only the listed termination models for this appliance; Duravent PolyPro concentric kits 2PPS-HKC / 3PPS-HKC; Centrotherm concentric kits ICWT242 / ICWT352.
- Z-Flex Z DENS horizontal termination kits: 2ZDHK2 (2 in) and 2ZDHK3 (3 in).
Applies to: Approved vent pipe and termination kits
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NPF installation and operation manual, p. 70-71. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.