Navien · Furnace troubleshooting
Annual service: burners, fan and electrical checks
What is going on
Component inspection items for annual service. The hot surface igniter is fragile.
Check in this order
- Inspect burners for deterioration.
- Use care on the burner assembly; the hot surface igniter breaks easily.
- Clean the flame sensor with fine steel wool or a Scotch-Brite pad and check that its wiring is tight and corrosion free.
- Check the circulating fan for dust buildup, debris and proper fastener tightness and alignment.
- Clean the motor ventilation ports if needed so air can cool the motor.
- Check all electrical connections for tightness and corrosion; repair any that are loose or corroded.
- Disconnect electrical power before working on the furnace.
Applies to: NDF forced air gas furnace
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NDF installation and operation manual, p. 91. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.