Navien · Furnace troubleshooting
Adjust gas/air ratio using a combustion analyzer
What is going on
Set the CO2 with a combustion analyzer, which the manual recommends. Confirm high altitude and gas type first.
Check in this order
- Turn on the gas and water supply (if a supply water valve is used).
- Remove the analyzer port cap and insert the analyzer probe into the port.
- Put the furnace in heating mode and set it to MIN (low fire).
- Read the CO2 and compare it with Table 2 for the model, altitude and gas type.
- If CO2 is off by more than 1.0%, turn the gas valve set screw using a 5/32 in or 4 mm Allen wrench. The screw is under a screw-on cover, so remove that first.
- Turn the screw no more than 1/4 turn clockwise raises CO2, counterclockwise lowers it.
- Put the furnace in heating mode and set it to MAX (high fire).
- Read CO2 at high fire. If it does not match Table 2, do not adjust the gas valve; check for the correct gas orifice instead.
- Once CO2 or offset values are confirmed, apply the conversion labels next to the rating plate.
- Reinstall the upper front cover, seat it fully against the furnace, and tighten the three knobs clockwise.
Applies to: NPF700 furnaces, gas conversion or altitude change
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NPF installation and operation manual, p. 136-137. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.