Annual service: furnace operation checks

NDF

What is going on

Checks a technician should run during annual inspection to confirm normal operation.

Check in this order

  1. Cycle the furnace and test all safety related controls.
  2. Confirm the temperature rise falls within the range on the rating plate.
  3. Confirm burner ignition is smooth and flames are smooth, soft blue, not impinging on the heat exchanger.
  4. Time the gas meter and/or check manifold pressure to confirm input matches the rating plate.
  5. Inspect the heat exchanger for corrosion; flue passages must be free of scale or excessive corrosion.

Applies to: NDF forced air gas furnace

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NDF installation and operation manual, p. 90-91. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.