Selecting approved vent pipe materials
What is going on
Venting rules differ in the US and Canada. Use approved materials only and never mix pipe types, as this can leak flue gas into the living space and void the warranty and certification. The default vent pipe material set for this product is Schedule 40 PVC.
Likely causes
- Mixing vent pipe materials
- Using unapproved cellular core PVC or CPVC, or Radel, for exhaust
Check in this order
- Use only approved vent materials for the locale (USA or Canada).
- Do not use cellular core PVC (ASTM F891), cellular core CPVC or Radel (polyphenolsulfone) for the exhaust vent.
- Do not use Schedule 40 or 80 polypropylene water or waste pipe in the vent run.
- Do not mix vent systems or manufacturers within a run.
- Use only the listed terminations from the same manufacturer as the vent system.
- For Canada, field-supplied plastic vent must be certified to ULC-S636 and come from one system manufacturer.
- Follow the vent manufacturer's instructions for installation details.
Applies to: Vent pipe and fitting selection
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NPF installation and operation manual, p. 69-71. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.