Setting the furnace on a level base and combustible surfaces

NPF

What is going on

The furnace must sit level so condensate drains properly. Do not install it directly on carpet or other combustible material; wood is the only combustible floor material allowed.

Check in this order

  1. Set the furnace on a level floor.
  2. If the floor is damp at times, raise the furnace on a concrete base about 1-1/2 in larger than the furnace base.
  3. Do not place the furnace on carpet.
  4. If on a combustible floor, the floor must be wood.

Applies to: NPF700 all models

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NPF installation and operation manual, p. 26-28. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.