Rheem · Furnace troubleshooting

Non-direct vent: alternate horizontal termination

96V96MDV

What is going on

This is the alternate horizontal terminal for a non-direct vent install, where the furnace draws combustion air from the room and only the exhaust goes outside. The one I get asked about is the height above grade. Keep the bottom of the termination at least 12 in (31 cm) above grade or the highest expected average snow level, whichever is higher, because buried vents are how people end up with blocked flues in February. In Canada, the termination must meet CSA B149.1-10, Sect. 8.14. A field-supplied reducing coupling is used where the pipe size changes, and a 2 in run of up to 18 in is allowed before the wall penetration when 3 in vent is used.

Likely causes

  • Site with deep snow or low grade where the terminal could get buried
  • Install in Canada where the code reference applies
  • Pipe size change from 3 in to 2 in near the wall
  • Alternate termination chosen because the standard one will not fit the wall layout

Check in this order

  1. Keep the termination at least 12 in above grade or expected snow level
  2. In Canada, follow CSA B149.1-10, Sect. 8.14
  3. Use a field-supplied reducing coupling to step from 3 in to 2 in pipe
  4. Limit 2 in pipe inside the building to 18 in before the penetration when using 3 in vent
  5. Seal the wall penetration and support the pipe so it holds its slope
  6. Have the finished vent inspected where local code requires it

Applies to: Non-direct vent horizontal termination (Option 3, Figures 19 and 20)

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Rheem 96V installation instructions, p. 56. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.