Oil furnace wiring: external relay and bonnet thermostat
What is going on
Oil furnace applications need an external relay. Dual fuel oil applications also need a bonnet thermostat.
Check in this order
- Wire the external relay as shown in Figure OIL-1.
- For dual fuel oil, add the BT bonnet thermostat THT1248 (BAYSEN03ATEMPAA).
- For dual fuel oil heat pump systems, cut the JP1 jumper on the control.
Applies to: Oil furnace and dual fuel oil applications
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Trane XR402 installer's guide 18-HD29D3-4, p. 9-11. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.