Trane · Furnace troubleshooting

Abnormal conditions and protection

AUH1B

What is going on

Summary of how the furnace responds to abnormal conditions.

Likely causes

  • Excessive combustion pressure from wind over 40 mph or vent/flue blockage
  • Loss of flame during heating
  • Power failure during heating
  • Gas supply failure
  • Induced draft blower failure
  • Condensate drain blockage

Check in this order

  1. Excessive pressure pressure switch opens and shuts off gas until pressure is acceptable.
  2. Loss of flame control closes gas valve, retries ignition, then locks out if ignition fails.
  3. Power failure ignition restarts automatically when power returns if thermostat still calls for heat.
  4. Draft blower failure unit will not start if pressure is not sensed.
  5. Condensate blockage pressure switch stays open until the drain is cleared and condensate flows freely.
  6. Lockout reset manually as described in the reset tip.

Applies to: AUH1B furnaces

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Trane installer's manual (AUH1B040A9241A), p. 41. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.