Lennox · Furnace troubleshooting

Furnace will not run (no heat) - Lennox SL297NV

What is going on

Before opening any panel on the Lennox SL297UHNV, check that the thermostat is actually calling and the furnace has power, gas and a clear filter. These are the basic checks from the manual when the furnace does not run at all. Treat the gas side with care and do not light or relight anything you are unsure about. The 7-segment display will usually give you an E-code, and E250 is the one a plugged filter produces. Watchguard lockout resets itself after 60 minutes, but you do not have to wait.

Likely causes

  • No heat call from the thermostat
  • Access panel off, so the door switch is open
  • Power off at the disconnect, fuse or breaker
  • Dirty filter tripping the limit (E250)
  • Gas off at the meter or at the main or internal manual valve
  • Ignition lockout (Watchguard)

Check in this order

  1. Confirm the thermostat is calling for heat
  2. Make sure access panels are secure so the door switch can close
  3. Check main disconnect, fuses and breakers
  4. Check the filter, a plugged filter will trip the limit (E250)
  5. Confirm gas is on at the meter and both the main and internal manual valves are open
  6. Check the 7-segment display for an E-code, if the unit is in Watchguard lockout (auto-retry after 60 minutes), move the thermostat from Heat to Off and back to Heat to restart
  7. If it locks out again, inspect for blockages and call a licensed technician for gas or ignition work

Applies to: SL297UHNV

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Lennox SL297UHNV Installation Instructions 507760-02 (02/2018), Failure To Operate and Heating Sequence, p.49. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.