Blower motor operating in power, temperature or speed limit (reduced airflow)

ACVC96AMVC96GCVC96GMVC96

What is going on

Furnace is limping along at reduced output. The blower motor has backed itself off on power, temperature or speed because airflow isn't what it expects. Check the filter first. Always the filter first.

Likely causes

  • Blocked filters
  • Restrictive or undersized ductwork
  • High ambient temperatures at the furnace location

Check in this order

  1. Check filters for blockage. Clean or replace them, or remove the obstruction.
  2. Check ductwork for blockage. Make sure every register is fully open.
  3. Verify the ductwork is sized correctly for the system. Resize or replace if needed.
  4. Check the installation location requirements for ambient temperature limits.
  5. Take a temperature rise reading across the furnace after fixes and compare to the rating plate.
  6. Run a full cycle and confirm the blower no longer limits.

Applies to: 34.5 in chassis gas furnaces

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Goodman GMVC96 Service and Troubleshooting, p. 63. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.