Goodman · Furnace troubleshooting

Airflow lower than demanded, furnace runs on low stage when high stage is expected

ACVC96AMVC96GCVC96GMVC96

What is going on

Not enough air moving. Control runs the furnace on low stage when it should be on high. Same story as most airflow calls, check the air path.

Likely causes

  • Blocked filters
  • Restrictive ductwork
  • Undersized ductwork

Check in this order

  1. Check the filters for blockage. Clean or replace, or remove the obstruction.
  2. Check ductwork for blockage. Verify all registers are fully open.
  3. Verify ductwork is appropriately sized. Resize or replace if needed.
  4. Check the return side too, closed dampers and blocked returns count.
  5. Measure temperature rise and compare to the rating plate.
  6. Run a call for high stage after the fix and confirm it stays there.

Applies to: 34.5 in chassis gas furnaces

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Goodman GMVC96 Service and Troubleshooting, p. 63. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.