All brands · Furnace troubleshooting

High blower-door ACH50 (>3)

What is going on

Blower-door test result over 3 ACH50 means the house envelope is leaky. That drives drafts, high heating and cooling bills and humidity problems, and it changes how combustion appliances and ventilation behave.

Likely causes

  • Leaky building envelope

Check in this order

  1. Run the blower-door test and depressurize the house to −50 Pa
  2. Locate leaks with a smoke pencil or thermal imaging while under pressure
  3. Seal the biggest leaks first, such as attic bypasses, rim joists, penetrations and window and door gaps
  4. Retest and confirm the ACH50 comes down
  5. Once tightened, check ventilation and combustion air so the house still breathes safely

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.