Does not start
What is going on
Furnace won't start. Go through the control circuit in order.
Likely causes
- Relay won't close or has dirty contacts
- Safety lockout open, bad relay coil, or low voltage
- Open high limit, stack switch or motor overload
- Broken or loose wires, open relay transformer
- Thermostat open from dirty contacts, or heat-sensing contacts out of place
Check in this order
- Turn power off, then check for loose or broken wires
- Meter the supply for low voltage
- Meter the transformer
- Check the thermostat contacts
- Check the high limit, stack switch and overload for continuity
- Check the relay coil and contacts
- Never jumper a safety, call a licensed tech
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.