Navien · Furnace troubleshooting

Installing the condensate trap (horizontal models)

NPF

What is going on

Horizontal models use a different hose route, with the trap connected through the side hole and secured with an overflow adapter and a hose bracket. Do not prime the trap by pouring water into the exhaust vent on these models.

Check in this order

  1. Turn each knob on the upper front cover counterclockwise, remove it, then pull the lower front cover back and off.
  2. Remove the plastic protector from the condensate trap connection hole.
  3. Insert the condensate hose into the trap connection hole and secure it.
  4. Remove the overflow cap from the overflow hose.
  5. Mount the condensate trap on the furnace with the two screws from the Installation Parts Kit, then fit the clip on the condensate drain adapter.
  6. Mount the overflow adapter on the furnace with four screws from the Installation Parts Kit, then fit the clip on the overflow hose.
  7. Attach the overflow hose to the drain adapter and overflow adapter, then fit the two fasteners.
  8. Mount the hose bracket on the furnace with two screws from the kit so the hose is held tightly.
  9. Push the lower front cover on, line up the upper front cover in its original position, make sure it is fully seated, and turn the three knobs clockwise to tighten.
  10. Place the free end of the drain line into an appropriate drain.

Applies to: Horizontal NPF700 models

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NPF installation and operation manual, p. 36-38. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.