Goodman · Furnace troubleshooting
Invalid memory card data
What is going on
This one shows up when the control module looked at the shared data set on the memory card and refused it. Usually the card doesn't match the furnace model, or the data didn't load right. It's an easy fix if you've got the right card.
Likely causes
- The integrated control module rejected the shared data set on the memory card
- Card is for a different model, or the data got corrupted
Check in this order
- Verify the shared data set is correct for the specific model. Re-populate using the correct memory card if needed.
- Turn power off before you start the repair.
- Use the memory card made for that specific model.
- Insert the memory card before you turn power on.
- Power up so the data loads, then turn power off again.
- The error clears once data is loaded and power is turned off.
Applies to: 34.5 in chassis gas furnaces
More furnace guides
- Airflow lower than demanded, furnace runs on low stage when high stage is expected
- Alternate combustion air opening (upflow or horizontal)
- Alternate vent/flue location (upflow or horizontal left)
- Annual inspection checklist
- Auxiliary limit control (location and purpose)
- Auxiliary limit switch open (blower compartment)
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Goodman GMVC96 Service and Troubleshooting, p. 62. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.