Navien · Furnace troubleshooting
Vent location precautions and condensate protection
What is going on
Avoid locations where flue condensate, freezing or recirculation can cause damage or problems.
Likely causes
- Flue gas condensate freezing on walls, soffits or nearby objects
- Recirculation of flue gases into the combustion air intake
- Condensate damaging shrubs, planters or finishes
Check in this order
- Caulk all cracks, seams or joints within a 6 ft (1.8 m) radius of the termination.
- Do not locate the terminal on the side of the building facing prevailing winter winds.
- Do not terminate under a deck unless there is adequate clearance; if piping runs under a deck, insulate it and suspend it so condensate cannot collect and freeze.
- Do not place the terminal where dripping condensate will fall on sidewalks, patios, planters or near windows where fogging or icing can occur.
- Keep the terminal away from shrubs and vegetation.
- Check that adjacent painted surfaces are in good condition, and seal wooden surfaces exposed to flue gases if needed.
- Do not terminate where condensate or vapor could affect regulators, relief valves or other equipment.
Applies to: NDF600 series furnaces
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NDF installation and operation manual, p. 26, 28, 32. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.