Navien · Furnace troubleshooting

Vent location precautions and condensate protection

NDF

What is going on

Avoid locations where flue condensate, freezing or recirculation can cause damage or problems.

Likely causes

  • Flue gas condensate freezing on walls, soffits or nearby objects
  • Recirculation of flue gases into the combustion air intake
  • Condensate damaging shrubs, planters or finishes

Check in this order

  1. Caulk all cracks, seams or joints within a 6 ft (1.8 m) radius of the termination.
  2. Do not locate the terminal on the side of the building facing prevailing winter winds.
  3. Do not terminate under a deck unless there is adequate clearance; if piping runs under a deck, insulate it and suspend it so condensate cannot collect and freeze.
  4. Do not place the terminal where dripping condensate will fall on sidewalks, patios, planters or near windows where fogging or icing can occur.
  5. Keep the terminal away from shrubs and vegetation.
  6. Check that adjacent painted surfaces are in good condition, and seal wooden surfaces exposed to flue gases if needed.
  7. Do not terminate where condensate or vapor could affect regulators, relief valves or other equipment.

Applies to: NDF600 series furnaces

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NDF installation and operation manual, p. 26, 28, 32. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.