All brands · Furnace troubleshooting
Heat exchanger leak
What is going on
Heat exchanger leak is a CO risk. Confirm it, don't guess. Test and report.
Likely causes
- Flame changes when the blower starts
- Visible rust, warp or crack
- Tracer test positive at the registers
- Or mechanical-room depressurization mimicking a leak
Check in this order
- Shut off the gas and power, and test for CO in the home
- Watch the burner flame as the blower starts, a flame that dances or leans points to a leak
- Inspect the exchanger with a mirror or camera for rust, warp and cracks
- Run a tracer gas test at the registers
- Rule out depressurization in the mechanical room as a cause
- If confirmed, red-tag the furnace and call a licensed tech
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.