Freeze protection for vent pipe in unheated spaces

UH1 / DH1

What is going on

Vent pipe through unheated space gets insulation.

Likely causes

  • Vent passes through an unheated space
  • Condensate freezing in uninsulated vent pipe and blocking flow
  • Unprotected domestic water pipes, which means the space is assumed to be unheated

Check in this order

  1. Insulate the vent pipe with 1/2 in (22.7 mm) thick Armaflex-type insulation or equal where it passes through unheated spaces.
  2. If the space is heated enough to prevent freezing, insulation is not required.
  3. If domestic water pipes in the space are not protected from freezing, treat the space as unheated.
  4. Check that the insulation covers the full run, including fittings.

Applies to: Horizontal and exposed vent runs

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Trane AUH1B080A9421B installer's manual, p. 24. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.