Goodman · Furnace troubleshooting

Delayed ignition - rough light-off

Goodman/Amana *MES9 single-stage

What is going on

Delayed ignition. Gas builds up in the chamber, lights late, thump. Gas work, licensed gas tech only. No bypassing safeties.

Likely causes

  • Wrong gas pressure
  • Burners not seated in their slots or not level
  • Carry-over (lighter tube) blocked
  • Burner orifice bent or out of line

Check in this order

  1. Qualified gas tech only. Never bypass or change safety controls.
  2. Check gas pressure, set to the rating plate value.
  3. Check burners sit in the locating slots, level front to rear and side to side.
  4. Clean the carry-over.
  5. Replace any deformed orifice or one not lined up with its burner.
  6. Watch several light-offs after, listen for the thump.

Applies to: GMES9, GCES9, AMES9, ACES9, VMES9, VCES9 (single stage, 92% and 96%)

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Goodman Service and Troubleshooting GMES9*/GCES9*/AMES9*/ACES9*/VMES9*/VCES9* (RS6612016r3) , S-312 Checking for Delayed Ignition p.44. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.