Installation checklist: power supply and condensate drain
What is going on
Electrical and drain checks to complete before startup.
Check in this order
- Confirm the supply voltage is 120V.
- Confirm the furnace is hard wired to line voltage and properly grounded.
- If a direct power connection is used, install a power switch for end-user maintenance.
- Check the polarity of the electrical connection.
- Run a condensate drain line from the furnace to a drain or condensate pump.
- On upflow and downflow models, confirm the drain trap is filled with water.
- Slope the drain line toward the drain port.
- Check that all condensate drain hoses are connected and secured.
- Install an anti-freeze device if required.
Applies to: NPF700 series (all listed models)
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NPF installation and operation manual, p. 92-93. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.