Noisy registers, drafts, blower overamps/ECM noise, coil freezing

What is going on

Noisy registers, drafts, a blower drawing high amps or ECM noise, and a freezing coil all point to airflow that has nowhere to go on a zoned system. When too few zones are open, the air has to be pushed through a small duct area. Check what the system is doing before touching anything, and keep power off when opening panels.

Likely causes

  • Too few zones open without a bypass
  • Airflow below the cfm per ton the equipment needs

Check in this order

  1. Turn off power before opening the furnace or inspecting the blower
  2. Count how many zones are open when the noise starts
  3. Install or check the barometric or motorized bypass damper
  4. Adjust the weight on the barometric arm to match the system
  5. Add a freezestat to protect the coil
  6. Measure airflow and confirm cfm per ton once the bypass is set
  7. For any limit on the zones, review the duct design with the installer

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.