Navien · Furnace troubleshooting

Evaporator coil installation and protecting the hydronic coil

NPF

What is going on

Install the coil upstream of the cooling unit and keep fasteners out of the hydronic coil area.

Likely causes

  • Long screws can puncture the hydronic coil.
  • Screws in the main cabinet near the hydronic coil can cause leaks.

Check in this order

  1. Install the furnace upstream of the evaporator coil when used together.
  2. Do not install screws in the main cabinet, especially where the hydronic coil sits.
  3. Fasten the coil only to the flanges at the supply air opening.
  4. Use screws 3/4 in (20 mm) or less on top (upflow) or bottom (downflow) of the furnace.
  5. Keep the 7 in (178 mm) area to avoid clear of screws and punctures on the side, back and top.

Applies to: NPF700 hydro-furnace upflow, horizontal and downflow models

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NPF installation and operation manual, p. 53-55. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.