This furnace is certified as a Category IV Type FSP furnace for non-direct and direct vent installations.

Check in this order

  1. For direct vent, supply all combustion air from outdoors through the plastic piping system; the 2 in PVC connector to the furnace is the only furnace-supplied component.
  2. Use the adapter gasket supplied with the combustion air adapter and keep the combustion air piping airtight.
  3. For non-direct vent with indoor combustion air, only a vent pipe is required and combustion air routing is not provided.
  4. Direct vent is the preferred method because it avoids using heated room air for combustion and is unaffected by exhaust fans or other negative pressure devices.
  5. If the furnace is installed near other fuel burning appliances, confirm there is adequate combustion air for the non-direct vent appliance.

Applies to: NDF600 series furnaces

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NDF installation and operation manual, p. 30. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.