Venting method overview (Category IV FSP)
What is going on
This furnace is certified as a Category IV Type FSP furnace for non-direct and direct vent installations.
Check in this order
- For direct vent, supply all combustion air from outdoors through the plastic piping system; the 2 in PVC connector to the furnace is the only furnace-supplied component.
- Use the adapter gasket supplied with the combustion air adapter and keep the combustion air piping airtight.
- For non-direct vent with indoor combustion air, only a vent pipe is required and combustion air routing is not provided.
- Direct vent is the preferred method because it avoids using heated room air for combustion and is unaffected by exhaust fans or other negative pressure devices.
- If the furnace is installed near other fuel burning appliances, confirm there is adequate combustion air for the non-direct vent appliance.
Applies to: NDF600 series furnaces
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NDF installation and operation manual, p. 30. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.