Combustion air and contamination checks

NPF

What is going on

Improper or insufficient combustion air can expose occupants to combustion products including carbon monoxide. Keep the furnace away from contaminated air sources, and isolate a non-direct vent furnace from contaminated rooms.

Likely causes

  • Chlorine-based pool chemicals, halogen refrigerants, cleaners, solvents, glues, paint removers and similar substances in the combustion air
  • Dust, debris, hair spray or spray detergents near the furnace

Check in this order

  1. Verify the combustion air supply is adequate.
  2. Keep the furnace away from the substances listed in the manual, including permanent wave solutions, chlorinated waxes, de-icing salts, carbon tetrachloride, printing inks, varnishes, hydrochloric acid and antistatic dryer softeners.
  3. For non-direct vent installs, duct combustion air from a nearby clean room or from outdoors (see section 2.11).

Applies to: NPF700 all models

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NPF installation and operation manual, p. 26. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.