Navien · Furnace troubleshooting
Choosing the furnace location and airflow orientation
What is going on
Locate the furnace centrally to the air distribution system and keep return grilles and registers open. Ducts cannot attach to the back of the furnace. Upflow models can take return on a side or the bottom. Horizontal left and downflow models must take return at the bottom (end opposite the discharge).
Check in this order
- Place the furnace centrally to the existing or planned duct system.
- Make sure return grilles and warm air registers are not blocked or closed.
- Upflow attach the return to either side or the bottom.
- Downflow and horizontal left attach the return to the bottom only.
- Keep the vent/flue routing and combustion air intake short; piping length can limit the location.
Applies to: Upflow, downflow and horizontal left NPF700
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NPF installation and operation manual, p. 25. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.