Downflow vent and drain layout options
What is going on
Downflow furnaces can use a left or right vent with the drain on the opposite side, internal or external. Air intake and exhaust cannot be on the top panel for downflow installations.
Check in this order
- Select the right or left vent layout from Figure 19.
- Select the drain side and internal or external trap mounting shown.
- Do not place the intake inlet or exhaust outlet on the top panel.
- Prime the trap and cut the drain hoses and pressure switch tubing to length.
Applies to: NDF downflow installations
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NDF Installation and Operation Manual, p. 43. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.