Navien · Furnace troubleshooting
Measure inlet gas pressure
What is going on
Licensed professional only. Furnace must have enough inlet gas pressure to run. Steps 2 to 7 are not on these pages.
Check in this order
- Shut off the manual gas valve on the gas supply line.
- Loosen the screw shown in the figure and connect a manometer to the pressure port.
- Zero the manometer before use.
- Reopen the manual gas valve and check all joints for leaks.
- Restart the furnace so the MAX setting runs the burner and fan at full capacity.
- At maximum firing rate, read the inlet gas pressure and confirm it is within the range for the gas type.
- Reinstall the upper front cover, seat it fully against the furnace, and tighten the three knobs clockwise.
Applies to: NPF700 hydro-furnace inlet gas pressure check
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NPF installation and operation manual, p. 49-50. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.