Trane · Furnace troubleshooting
Start-of-season inspection checklist
What is going on
Qualified service agency checks the installation before each heating season. Check venting, return duct, base support, burner flame, and combustion and ventilation air.
Check in this order
- Confirm all flue passages outside the unit (chimney, vent connector) are clear of obstructions.
- Confirm the vent connector is in place, slopes upward, and has no holes or heavy corrosion.
- Confirm the return air duct is sound, sealed to the unit, and terminates outside the space containing the unit.
- Confirm the unit support is solid with no sagging, cracks or gaps, and the base is sealed to the support.
- Look for obvious signs of deterioration on the unit.
- Check burner flames they should be bright blue, steady, not erratic, and extend up to the heat exchanger.
- Confirm air openings and the space around the unit are unobstructed for combustion and ventilation air.
Applies to: Gas heating system, start of heating season
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Trane gas heating system owner's information 32-5083-1C-EN, p. 2. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.