Oil on floor

What is going on

Oil on the floor around the furnace is not something to wait on. It is a fire and cleanup problem, and it usually means a fitting has loosened or the pump shaft seal is leaking. Figure out exactly where it is coming from before you wipe it up, so you fix the right thing.

Likely causes

  • Loose fittings or unions on the oil line
  • Leaking pump shaft seal
  • Air in the line, which can make the pump gauge flutter and weep at joints

Check in this order

  1. Wipe the area dry, then run the burner and watch where oil appears
  2. Tighten flare fittings and unions, and replace any that are damaged
  3. Check around the pump shaft seal and replace the pump if it is weeping
  4. Fit a gauge and watch for needle flutter, which points to air in the line
  5. Bleed the pump and recheck all joints
  6. Have a licensed oil tech handle any large spill or tank leak

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.