Navien · Furnace troubleshooting
Convert condensate drain and water connections from left to right
What is going on
The furnace ships with the auto water fill connection and junction box on the right side, with the condensate hose set for left side installs. Use this procedure to convert for right side installs.
Check in this order
- Turn off power and remove the upper front cover knobs (turn counterclockwise), then remove the upper and lower front covers.
- Disconnect the condensate drain hose, junction box, supply water assembly, and drain trap assembly. Loosen hose fasteners with pliers.
- Move the grommets from the left side to the right side: gas pipe, condensate, electrical line, overflow and gas pipe, screw hole, and supply water.
- Replace the drain trap assembly with the included right condensate drain hose and overflow hose. Assemble with the condensate adapter and hose fasteners as shown.
Applies to: NPF700 Upflow and Downflow Hydro-furnace
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NPF installation and operation manual, p. 87-88. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.