Blower motor loss of rotor control or high current trip

ACVC96AMVC96GCVC96GMVC96

What is going on

This fault means the circulator blower motor lost track of its rotor, or it saw a surge of current, and the control shut the furnace down. In plain words, the motor was suddenly working a lot harder than it should. Think about anything that could jam it or choke its air. Dirty filters, blocked registers and something stuck in the blower wheel are all common, so check those before you condemn the motor. Power off first, because that wheel can start without warning.

Likely causes

  • Abnormal motor loading
  • Sudden change in speed or torque
  • Sudden blockage of furnace air inlet or outlet
  • Debris or a loose wheel rubbing in the housing

Check in this order

  1. Turn power off before repair
  2. Check filters, filter grills, registers, duct system and furnace air inlet and outlet for blockages
  3. Check the circulator blower for obstructions. Remove and repair or replace the wheel or motor if needed
  4. Spin the wheel by hand and feel for drag or noise in the bearings
  5. Replace the motor or wheel with the correct replacement part if needed
  6. Restore power and watch a full cycle for a repeat fault

Applies to: 34.5 in chassis gas furnaces

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Goodman GMVC96 Service and Troubleshooting, p. 63. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.