Outdoor air from attic or crawl space (Case 3) install notes
What is going on
Attic air is used only if the attic is adequately vented and the opening is above the insulation.
Likely causes
- Attic exhaust fan creating negative pressure
Check in this order
- Use one opening from the floor drawing from the ventilated crawl space, and one opening that connects freely to the ventilated attic.
- If using attic air, duct the opening from the ceiling high enough to be above the insulation.
- Make sure the attic is vented with soffit or gable vents.
- As an option, drop a duct from the attic ending 12 in (305 mm) above the floor.
Applies to: NDF600 series furnaces with attic or crawl space air
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NDF Forced Air Gas Furnace Installation and Operation Manual, p. 22. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.