All brands · Furnace troubleshooting
Water flows with furnace off
What is going on
Water keeps flowing to the humidifier after the furnace has shut down. Left alone it can overflow the pan, run down the drain constantly, or stain the plenum, so deal with it soon.
Likely causes
- Solenoid valve not seating because of scale or debris on the seat, since a valve that is stuck partly open lets water bypass
- Solenoid wiring fault that keeps the coil energized or feeds it from the wrong circuit
Check in this order
- Shut off power to the furnace and humidifier first, then close the humidifier saddle valve
- Inspect the solenoid wiring against the manual and look for a short or miswired lead
- Restore power with the furnace idle and meter the solenoid coil, it should read zero volts with no call
- Pull the valve and clean the seat and inlet screen of mineral deposits
- Replace the solenoid valve if it still passes water when de-energized
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.