Navien · Furnace troubleshooting
Freeze protection for furnace, trap and drain
What is going on
Where the furnace may reach near 32°F (0°C), such as an alcove or attic, insulate the drain trap, drain pipe and supply water line. Exposed drain piping must be protected from freezing. Heat tape or heating cable rated 3–6 W/ft that is UL or CSA listed/approved is acceptable.
Check in this order
- Insulate the drain trap, drain pipe and supply water line where freezing is possible.
- Protect exposed drain piping from freezing.
- If heat tape is used, rate it at 3–6 W/ft, UL or CSA listed/approved, and install and maintain it per the maker's instructions.
- Check heat tape operation at installation.
Applies to: NPF700 all models
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NPF installation and operation manual, p. 27. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.