Return air ductwork sealing and joist space safety
What is going on
Poor sealing or gas piping in return joist spaces can pull combustion products into the living space.
Likely causes
- Return air joist space shared with plumbing stacks or chimney components
- Return air ductwork not sealed to the furnace
- Flue products entering supply or return ductwork
Check in this order
- Do not route gas piping through joist spaces used for return air.
- Do not use a joist space for return air if it holds plumbing stacks or chimney parts, unless the return portion is fully isolated.
- Seal all return air ductwork to the furnace with sheet metal screws.
- Tape the sheet metal seams near the furnace with duct tape or similar material.
- If the furnace sits on a platform with bottom return, seal it airtight between the furnace and the return plenum.
- Support the platform solidly so it does not sag, and seal between the support and the base.
- Make sure flue products cannot enter the return or supply ductwork.
Applies to: NDF600 series furnaces
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NDF Forced Air Gas Furnace Installation and Operation Manual, p. 17. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.