Trane · Furnace troubleshooting

Downflow furnace on combustible floor (subbase)

UH1/DH1

What is going on

DH1 downflow on a combustible floor. Can't sit it right on carpet, tile or any combustible flooring. Wood flooring is the exception. Use the subbase.

Likely causes

  • Not a fault. Floor protection requirement for a downflow install.

Check in this order

  1. Put subbase BAYBASE-205 between the furnace and combustible flooring on vertical downflow installs.
  2. Downflow vertical with a cased coil? No subbase needed.
  3. Cut the floor opening to the dimensions in Table 1.
  4. Check the opening is square and clear of joists or wiring.
  5. Seat the furnace on the subbase and confirm no gaps around it.
  6. Check clearances to combustibles on the rating plate before leaving.

Applies to: DH1 downflow furnaces

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Trane installer's guide 18-CD29D1-11, p. 8. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.