Goodman · Furnace troubleshooting

Lockout after excessive ignition retries (3 total)

ACVC96AMVC96GCVC96GMVC96

What is going on

So the furnace tried to light three times and gave up, and now it's locked out. That just means the control never proved flame, so it shut the gas off for safety. Most of the time it comes down to something simple like a dirty flame sensor, but you want to check the gas and the igniter too.

Likely causes

  • No gas getting to the burners, or a front cover pressure switch stuck open
  • A bad or misaligned igniter, or the wrong orifices
  • A flame sensor that is coated, oxidized or connected badly

Check in this order

  1. Turn the power off before you start any repair.
  2. Clean the flame sensor with steel wool, since a coated rod is the most common reason a flame drops out.
  3. Handle the igniter gently, it is fragile, and check that it sits where it should.
  4. Check the vent and flue piping against the vent section of the manual.
  5. Confirm gas is reaching the burners. Gas pressure and orifice work goes to a licensed gas tech.
  6. Reset the lockout and watch a full ignition cycle.

Applies to: 34.5 in chassis gas furnaces

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Goodman GMVC96 Service and Troubleshooting, p. 60. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.