Navien · Furnace troubleshooting
Concentric vent terminal installation
What is going on
A concentric kit lets one wall penetration handle both combustion air intake and exhaust. Use an approved IPEX kit and follow the kit maker instructions for the install.
Check in this order
- Use only an approved kit 2 in IPEX kit 196005 or 3 in IPEX kit 196006.
- If 1-1/2 in vent material is used with a concentric kit, use an increaser coupling to connect to the 2 in concentric kit.
- Follow the concentric terminal manufacturer instructions for the install.
- Offset straight vertical runs so condensate is pushed against the vent walls.
Applies to: Concentric venting with approved IPEX kits
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NDF installation and operation manual, p. 32. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.