Navien · Furnace troubleshooting

Routine homeowner checks

NDF

What is going on

Quick inspection to do each time the air filter is checked. Venting and terminals must be kept clear and sealed.

Check in this order

  1. Look for obvious signs of deterioration on the furnace.
  2. Confirm venting and combustion air piping are still fastened to the furnace and do not sag.
  3. Check that venting slopes up about 1/4 in per foot (6 mm per 305 mm) toward the outside wall or termination.
  4. Look for water marks on the floor under the venting; these may mean a leaking pipe joint.
  5. Confirm all ductwork is secured to the furnace and solidly supported.
  6. Check that the condensate drain line flows freely; debris in the line should be reported to the service contractor.
  7. Inspect the combustion air and exhaust terminals for obstructions and debris; clear any screens of debris, corrosion or anything blocking airflow.

Applies to: NDF forced air gas furnace

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NDF installation and operation manual, p. 90-91. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.