Trane · Furnace troubleshooting
Upflow furnace with cased coil attachment
What is going on
Before you set a factory cased coil on a Trane UH1 upflow furnace, read the installer's guide and gather the standoffs and screws that came with the coil. The coil mounts to the top flanges of the furnace and always sits downstream of the furnace airflow. Shut off power and gas to the furnace while you work.
Likely causes
- Not a fault call. This is a mounting procedure for an upflow furnace with a cased coil.
Check in this order
- Use the standoffs and screws included with the cased coil, and do not substitute hardware.
- Locate the clearance alignment holes near the bottom of the coil wrapper.
- Insert each standoff into the cabinet alignment hole.
- Drive the drill screws through the standoffs and into the furnace top flange.
- Confirm the coil sits square and the joint between coil and furnace is tight.
- Seal any gaps per the installer's guide so conditioned air does not leak.
Applies to: Upflow UH1 furnaces with cased coil
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Trane installer's guide 18-CD29D1-11, p. 8. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.