All brands · Furnace troubleshooting

Unsatisfactory heat (short cycles / uneven / not enough)

What is going on

Unsatisfactory heat on a furnace usually shows up as short cycling, uneven rooms or just not enough warmth. In my experience it is rarely one thing. A cycling limit from poor airflow, a flame sensor reading low, or a thermostat in a bad spot are the usual suspects, and I go through them in that order.

Likely causes

  • Faulty thermostat
  • Faulty limit or an open auxiliary limit
  • Flame sensor reading low microamps
  • Wrong heat anticipator setting
  • Improper airflow or distribution, or a bad thermostat location

Check in this order

  1. Test the thermostat
  2. Test the limit, and manually reset an open auxiliary limit once, then find out why it tripped
  3. Test the flame sensor and clean it if the microamp reading is low
  4. Check the anticipator setting
  5. Check duct static pressure (see A34)
  6. Relocate the thermostat if it sits near a register, sunlight or an outside wall

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.